Desa VP2600TB AIR for Combustion and Ventilation, Ventilation AIR, Ventilation Air From Outdoors

Page 6

®

INFRARED PROPANE/LP GAS HEATER

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

12"

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

6

104821

Image 6
Contents Infrared VENT-FREE PROPANE/LP GAS Heater What to do if YOU Smell GASSafety Information Infrared PROPANE/LP GAS HeaterProduct Identification Product FeaturesSafety Device Local Codes UnpackingUnusually Tight Construction Fresh AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building AIR for Combustion and VentilationVentilation AIR Ventilation Air From OutdoorsLocating Heater InstallationInstallation Items Check GAS TypeRemoving Front Panel Of Heater Installing Heater to WallMounting Bracket Methods For Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Connecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing Gas Supply Piping System For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterThermostat Control Operation Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off HeaterCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Gas leak. See Warning statement at Service Publications Technical SpecificationsReplacement Parts Service HintsIllustrated Parts Breakdown Parts List KEY Part Number Description QTYVP2600TB Parts List Floor Mounting Stand AccessoriesEquipment Shutoff Valve GA5010 Models VP1600TB GA4000B Models VP2600TB GA4010B104821 Warranty Information

VP1600TB, VP2600TB specifications

The Desa VP2600TB and VP1600TB are advanced ventilation and heating products designed to enhance indoor air quality and provide comfort through efficient temperature management. These models are particularly suitable for residential and commercial spaces that require reliable heating solutions without compromising on energy efficiency.

One of the standout features of both the VP2600TB and VP1600TB is their innovative heating technology. These units utilize a high-efficiency heating element that significantly reduces energy consumption while delivering consistent warmth. The VP2600TB is designed for larger spaces, offering a powerful output for effective heating, while the VP1600TB caters to smaller areas, making it an ideal choice for localized heating needs.

The thermostatic control feature allows users to set and maintain their desired temperature easily. With an integrated digital thermostat, both models ensure that users can monitor and adjust heating levels with precision, minimizing waste and optimizing comfort. This feature is particularly appealing in fluctuating weather conditions where a reliable temperature regulation system is essential.

In terms of design, both models feature a sleek and modern aesthetic that can seamlessly blend into various interior decors. The compact design of the VP1600TB makes it perfect for smaller rooms, while the robust structure of the VP2600TB ensures durability and longevity for heavy-duty use.

Another key characteristic of the Desa VP series is their safety features. Both models come equipped with a safety shut-off mechanism that activates in the event of overheating, providing peace of mind for users. Moreover, the burnished steel construction and cool-touch housing are engineered to reduce the risk of accidental burns and enhance the overall safety profile.

The VP2600TB and VP1600TB also incorporate advanced filtration systems that help improve indoor air quality. These units utilize high-capacity filters to capture dust, allergens, and other airborne particles, ensuring that the air circulated within the space is clean and healthy.

In summary, the Desa VP2600TB and VP1600TB offer a comprehensive solution for heating and ventilation needs, combining efficiency, safety, and advanced technology in one package. Their ability to adapt to various environments while maintaining energy efficiency makes them an excellent investment for anyone looking to enhance comfort within their space.