Desa VP1600TB AIR for Combustion Ventilation, Determining FRESH-AIR Flow for Heater Location

Page 5

OWNER’S MANUAL

AIR FOR

COMBUSTION AND

VENTILATION

Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = ________________________ cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

_____________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater

________________ Btu/Hr

 

 

 

 

Gas water heater*

________________ Btu/Hr

Example:

 

 

 

Gas furnace

________________ Btu/Hr

 

 

 

Gas water heater

 

40,000

Btu/Hr

Vented gas heater

________________ Btu/Hr

 

Vent-free heater

+

18,000

Btu/Hr

Gas fireplace logs

________________ Btu/Hr

 

 

 

 

Total

=

58,000

Btu/Hr

Other gas appliances*

+ ________________ Btu/Hr

 

 

 

 

Total

= ________________ Btu/Hr

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________________ Btu/Hr (maximum the space can support)

_________________ Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space can support) 58,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.

C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes.

Continued

104821

5

Image 5
Contents What to do if YOU Smell GAS Infrared VENT-FREE PROPANE/LP GAS Heater Infrared PROPANE/LP GAS Heater Safety InformationSafety Device Product FeaturesProduct Identification Local Codes UnpackingProviding Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation Items InstallationLocating Heater Check GAS TypeMounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Typical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Turn OFF GAS To Appliance Lighting InstructionsThermostat Control Operation Shutting Off HeaterInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Gas leak. See Warning statement at Replacement Parts SpecificationsService Publications Technical Service HintsIllustrated Parts Breakdown KEY Part Number Description QTY Parts ListVP2600TB Parts List Equipment Shutoff Valve GA5010 AccessoriesFloor Mounting Stand Models VP1600TB GA4000B Models VP2600TB GA4010B104821 Warranty Information