IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, and car- bon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to natural gas. The odor helps you detect a natural gas leak. However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use any accessory not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will re- main hot for a time after shut- down. Allow surface to cool be- fore touching.

Carefully supervise young chil- dren when they are in the same room with heater.

Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.This heater needs fresh, outside air ven- tilation to run properly. This heater has an oxygen depletion sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6.

4.Keep all air openings in front and bot- tom of heater clear and free of debris. This will insure enough air for proper combustion.

5.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

6.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

7.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

8.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

9.Turn off heater and let cool before ser- vicing. Only a qualified service person should service and repair heater.

10.Operating heater above elevations of 4,500 feet could cause pilot outage.

2

104271

Image 2
Contents OWNER’S Operation and Installation Manual VN600BA What to do if YOU Smell GASSafety Information Blue Flame Natural GAS HeaterLocal Codes Product FeaturesProduct UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing Heater to Wall InstallationInstallation Items Locating HeaterPlacing Heater On Mounting Screws Installing Two Mounting ScrewsInstalling Bottom Mounting Screw Removing Front Panel Of HeaterConnecting to GAS Supply Gas ConnectionPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Shutting Off HeaterCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Observed Problem Possible Cause Illustrated Parts Breakdown VN600BAParts List KEY Part Number Description QTYTechnical Service SpecificationsReplacement Parts Service Hints104271 Warranty Information

VN600BA specifications

The Desa VN600BA is a versatile and efficient vent-free heater that has garnered attention for its performance and user-friendly design. This model stands out in the market due to its blend of advanced technologies and practical features, making it an attractive choice for homeowners seeking reliable heating solutions.

One of the key features of the Desa VN600BA is its innovative vent-free design, which allows for easy installation in various settings without the need for ductwork. This not only reduces installation costs but also enhances flexibility in terms of placement, enabling homeowners to heat different areas of their homes effectively. The heater operates using natural gas or propane, providing options for users based on their fuel availability and preferences.

The VN600BA is equipped with a powerful heating capacity, capable of delivering up to 30,000 BTUs per hour. This makes it suitable for heating spaces up to 1,000 square feet, ensuring comfortable temperatures during colder months. The adjustable thermostat feature allows for precise temperature control, enhancing user comfort while optimizing energy consumption. Additionally, it includes a safety pilot system that monitors the flame and automatically shuts off the gas flow in case of any irregularities, ensuring safety at all times.

The aesthetic appeal of the Desa VN600BA cannot be overlooked. With its sleek design and attractive finish, it complements different interior styles while serving as a functional heating solution. The heater also features a convenient control panel that allows users to operate the device with ease.

In terms of energy efficiency, the Desa VN600BA is designed to minimize waste while providing effective heating. Being vent-free, it utilizes the fuel it consumes more efficiently compared to traditional heating systems, translating to lower utility bills. Moreover, its design promotes complete combustion, which contributes to cleaner operation and reduced environmental impact.

In summary, the Desa VN600BA vent-free heater is characterized by its efficient heating capacity, flexible installation options, and user-friendly features. Its advanced safety systems, combined with an attractive design, make it a desirable choice for homeowners looking for a reliable and efficient heating solution. Whether for supplemental or primary heating, the VN600BA offers a compelling combination of performance and style, ensuring that it remains a preferred option in the market.