VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op-

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

tion 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventila- tion grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermo- stat-controlled power vent. Heated air enter- ing the attic will activate the power vent.

12"

Figure 2 - Ventilation Air from Inside Building

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

6

104271

Image 6
Contents OWNER’S Operation and Installation Manual VN600BA What to do if YOU Smell GASSafety Information Blue Flame Natural GAS HeaterLocal Codes Product FeaturesProduct UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Heater to Wall InstallationInstallation Items Locating HeaterPlacing Heater On Mounting Screws Installing Two Mounting ScrewsInstalling Bottom Mounting Screw Removing Front Panel Of HeaterConnecting to GAS Supply Gas ConnectionPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Shutting Off HeaterCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Observed Problem Possible Cause Illustrated Parts Breakdown VN600BAParts List KEY Part Number Description QTYTechnical Service SpecificationsReplacement Parts Service Hints104271 Warranty Information

VN600BA specifications

The Desa VN600BA is a versatile and efficient vent-free heater that has garnered attention for its performance and user-friendly design. This model stands out in the market due to its blend of advanced technologies and practical features, making it an attractive choice for homeowners seeking reliable heating solutions.

One of the key features of the Desa VN600BA is its innovative vent-free design, which allows for easy installation in various settings without the need for ductwork. This not only reduces installation costs but also enhances flexibility in terms of placement, enabling homeowners to heat different areas of their homes effectively. The heater operates using natural gas or propane, providing options for users based on their fuel availability and preferences.

The VN600BA is equipped with a powerful heating capacity, capable of delivering up to 30,000 BTUs per hour. This makes it suitable for heating spaces up to 1,000 square feet, ensuring comfortable temperatures during colder months. The adjustable thermostat feature allows for precise temperature control, enhancing user comfort while optimizing energy consumption. Additionally, it includes a safety pilot system that monitors the flame and automatically shuts off the gas flow in case of any irregularities, ensuring safety at all times.

The aesthetic appeal of the Desa VN600BA cannot be overlooked. With its sleek design and attractive finish, it complements different interior styles while serving as a functional heating solution. The heater also features a convenient control panel that allows users to operate the device with ease.

In terms of energy efficiency, the Desa VN600BA is designed to minimize waste while providing effective heating. Being vent-free, it utilizes the fuel it consumes more efficiently compared to traditional heating systems, translating to lower utility bills. Moreover, its design promotes complete combustion, which contributes to cleaner operation and reduced environmental impact.

In summary, the Desa VN600BA vent-free heater is characterized by its efficient heating capacity, flexible installation options, and user-friendly features. Its advanced safety systems, combined with an attractive design, make it a desirable choice for homeowners looking for a reliable and efficient heating solution. Whether for supplemental or primary heating, the VN600BA offers a compelling combination of performance and style, ensuring that it remains a preferred option in the market.