Desa VN6C Technical Service, Service Publications Replacement Parts, Specifications, Accessory

Page 15

OWNER’S MANUAL

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.

SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

SPECIFICATIONS

 

VN10

VN6C

Btu (Variable)

5,500/10,000

6,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator

 

 

Setting

3" W.C.

3" W.C.

Inlet Gas Pressure (inches of water)

 

Maximum

10.5"

10.5"

Minimum

4"

4"

Dimensions, Inches (H x W x D)

 

Heater

20 1/2 x 13 1/2 x 5

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

25 x 16 11/16 x 7 1/2

Weight (pounds)

 

 

Heater

14

13

Shipping

18

17

Contact authorized dealer from whom you purchased this product. If they cannot sup- ply original replacement part(s), call DESA International’s Technical Service Depart- ment at 1-800-323-5190 for referral infor- mation.

When contacting your dealer or DESA In- ternational, have ready:

your name

your address

model number of your heater

how heater was malfunctioning

type of gas used (propane/LP or natu- ral gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they cannot supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

SERVICE HINTS

When gas pressure is too low

pilot will not stay lit

burner(s) will have delayed ignition

heater will not produce specified heat

When gas quality is bad

pilot will not stay lit

burner(s) will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

ACCESSORY

Purchase this heater accessory from your local dealer. If they cannot supply this ac- cessory, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual.

MANUAL

SHUTOFF

VALVE -

GA5010

Manual shutoff valve with 1/8" NPT tap.

When calling DESA International, have ready:

model number of your heater

the replacement part number

101851

15

Image 15
Contents Models VN6C and VN10 Infrared VENT-FREE Natural GAS HeaterVanguard VN6C and VN10 Natural GAS Heater Safety InformationLocal Codes Product FeaturesProduct Identification AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type Installing to WallInstallation Items Installing Heater to WallRemoving Front Panel of Heater Installing TWO Mounting ScrewsInstalling Bottom Mounting Screw Placing Heater on Mounting ScrewsGas Connection Connecting to GAS SupplyChecking GAS Connections OperatingHeater To Turn OFF GAS To Appliance Operating HeaterLighting Instructions To Select Heating LevelInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Gas leak. See Warning statement be Service Hints Technical ServiceService Publications Replacement Parts SpecificationsVN6C Parts ListVN10 Vanguard VN6C and VN10 Natural GAS Heater 101851 Warranty Information