Desa Tech RFN28TD Lighting Instructions, To Turn OFF GAS To Appliance, Manual Lighting Procedure

Page 14

15,000 TO 28,000 BTU/HR VENT-FREE NATURAL GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information on page 13, column 3.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

Ignitor Button

Control Knob

 

LO

 

PILOT

 

OFF

 

HI

IGNITOR

 

Figure 23 - Control Knob In The OFF Position

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information on page 13, column 3. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

C-clockwiseto the PILOT position. Press in control knob for five (5) seconds (see Figure 23).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 16 through 18. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

Ignitor Electrode

Thermocouple

Pilot Burner

 

Figure 24 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise Clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on this heater differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or de- creases the burner flame height. At times the room may exceed the set tempera- ture. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set tem- perature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 2, page 4).

2.Follow steps 1 through 5 under Lighting Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

5.Replace front panel.

14

104779

Image 14
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information 15,000 to 28,000 BTU/HR VENT-FREE Natural GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingAssembling Heater AssemblyInstalling Log Removing Front Panel Of HeaterAssembling and Attaching Brass Trim AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Heater InstallationInstallation Items Check GAS TypeMounting Heater to Wall Installation OptionsThermostat Sensing Bulb Attaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Placing Heater On Mounting BracketSee instructions included with mantel kit Assembling Mantel Securing Hearth Base to FloorMounting Heater to Optional Hearth Base Connecting to GAS Supply Gas ConnectionPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Thermostat Control OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atTechnical Service SpecificationsReplacement Parts Service HintsParts Centrals Accessories Illustrated Parts Breakdown RFN28TDParts List KEY Part Number Description QTYWarranty Information

RFN28TD specifications

Desa Tech RFN28TD is a notable advancement in the realm of remote communication technology, specifically designed to meet the increasing demands of modern industries. This radio frequency network device is tailored to enable seamless communication across various platforms, making it indispensable for organizations looking to enhance their operational efficiency.

One of the key features of the RFN28TD is its robust dual-band functionality, which operates across both the 2.4 GHz and 5 GHz frequency bands. This dual-band capability allows the device to adapt to varying environmental conditions, providing users with a stable and reliable connection even in congested areas. The RFN28TD is equipped with advanced adaptive transmission technology, ensuring optimal performance and quality of service by dynamically selecting the best frequency for transmission.

Another significant characteristic of the RFN28TD is its long-range communication capability. With an impressive range of up to several kilometers under optimal conditions, this device is ideal for applications requiring extensive coverage, such as industrial automation, smart cities, and agricultural monitoring. The built-in high-gain antennas further enhance its reach, allowing for improved signal penetration through obstacles.

The RFN28TD is also designed with security in mind. It incorporates advanced encryption protocols, ensuring that data transmitted over the network is secure and protected from unauthorized access. This is particularly crucial for businesses handling sensitive information, as data breaches can lead to severe consequences.

In terms of ease of use, the device offers a user-friendly interface that simplifies the setup and management processes. Its plug-and-play design allows for quick installation, making it accessible even for users with minimal technical expertise. Additionally, the RFN28TD supports a wide range of connectivity options, including Ethernet and Wi-Fi, further enhancing its versatility.

Energy efficiency is another highlight of the RFN28TD, as it operates on lower power consumption compared to traditional communication devices. This not only reduces operational costs but also contributes to a greener, more sustainable approach to technology.

In conclusion, the Desa Tech RFN28TD is a powerful and versatile communication device that combines advanced features, long-range capabilities, robust security, and energy efficiency. Its adaptability to various applications makes it an essential tool for businesses and industries aiming to leverage the benefits of modern communication technologies.