Desa Tech RFN28TD Thermostat Sensing Bulb, Installation Options, Mounting Heater to Wall

Page 9

OWNER’S MANUAL

INSTALLATION

Continued

THERMOSTAT SENSING BULB

The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Locating Thermostat Sensing Bulb

1.Remove front panel of heater (see Fig- ure 2, page 4).

2.Locate thermostat sensing bulb just under burner assembly.

IMPORTANT: Attach thermostat sensing bulb to back of heater for proper operation.

INSTALLATION OPTIONS

There are three options for mounting this heater.

A.Mounting heater to wall

B.Mounting heater to optional hearth base

C.Mounting heater with optional hearth base to optional mantel

A. MOUNTING HEATER TO WALL

Mounting Bracket

The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

WARNING: Maintain minimum clearances shown in Figure 13. If you can, provide greater clear- ances from floor and joining wall.

2.Mark screw locations on wall (see Fig- ure 13).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

Attaching Thermostat Sensing Bulb

1.Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.

2.Place clamp on thermostat sensing bulb as shown in Figure 11. Clamp is pro- vided in hardware package.

3.Snap clamp into upper mounting hole as shown in Figure 11. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Thermostat

Sensing Bulb

Clamp

Figure 11 - Attaching Thermostat Sensing Bulb

Mounting

Bracket

Figure 12 - Mounting Bracket Location

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching to wall stud This method pro- vides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to wall anchor This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

11"

16"

Min.

 

AdjoiningWall

 

Only Insert Mounting

20 3/4"

Screws Through Last

Min.

Hole On Each End

 

Floor

Figure 13 - Mounting Bracket Clearances

Continued

104779

9

Image 9
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual15,000 to 28,000 BTU/HR VENT-FREE Natural GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingInstalling Log AssemblyAssembling Heater Removing Front Panel Of HeaterProviding Adequate Ventilation AIR for Combustion and VentilationAssembling and Attaching Brass Trim Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Items InstallationLocating Heater Check GAS TypeInstallation Options Thermostat Sensing BulbMounting Heater to Wall Mounting Heater on Optional Hearth Base Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Placing Heater On Mounting BracketSecuring Hearth Base to Floor Mounting Heater to Optional Hearth BaseSee instructions included with mantel kit Assembling Mantel Gas Connection Connecting to GAS SupplyPressure Testing Gas Supply Piping System For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at TopReplacement Parts SpecificationsTechnical Service Service HintsParts Centrals Accessories RFN28TD Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListWarranty Information

RFN28TD specifications

Desa Tech RFN28TD is a notable advancement in the realm of remote communication technology, specifically designed to meet the increasing demands of modern industries. This radio frequency network device is tailored to enable seamless communication across various platforms, making it indispensable for organizations looking to enhance their operational efficiency.

One of the key features of the RFN28TD is its robust dual-band functionality, which operates across both the 2.4 GHz and 5 GHz frequency bands. This dual-band capability allows the device to adapt to varying environmental conditions, providing users with a stable and reliable connection even in congested areas. The RFN28TD is equipped with advanced adaptive transmission technology, ensuring optimal performance and quality of service by dynamically selecting the best frequency for transmission.

Another significant characteristic of the RFN28TD is its long-range communication capability. With an impressive range of up to several kilometers under optimal conditions, this device is ideal for applications requiring extensive coverage, such as industrial automation, smart cities, and agricultural monitoring. The built-in high-gain antennas further enhance its reach, allowing for improved signal penetration through obstacles.

The RFN28TD is also designed with security in mind. It incorporates advanced encryption protocols, ensuring that data transmitted over the network is secure and protected from unauthorized access. This is particularly crucial for businesses handling sensitive information, as data breaches can lead to severe consequences.

In terms of ease of use, the device offers a user-friendly interface that simplifies the setup and management processes. Its plug-and-play design allows for quick installation, making it accessible even for users with minimal technical expertise. Additionally, the RFN28TD supports a wide range of connectivity options, including Ethernet and Wi-Fi, further enhancing its versatility.

Energy efficiency is another highlight of the RFN28TD, as it operates on lower power consumption compared to traditional communication devices. This not only reduces operational costs but also contributes to a greener, more sustainable approach to technology.

In conclusion, the Desa Tech RFN28TD is a powerful and versatile communication device that combines advanced features, long-range capabilities, robust security, and energy efficiency. Its adaptability to various applications makes it an essential tool for businesses and industries aiming to leverage the benefits of modern communication technologies.