OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1.

Ignitor electrode positioned wrong

1.

Replace pilot assembly

2.

Ignitor electrode broken

2.

Replace pilot assembly

3.

Ignitor electrode not connected to igni-

3.

Reconnect ignitor cable

 

tor cable

 

 

4.

Ignitor cable pinched or wet

4.

Free ignitor cable if pinched by any

 

 

 

metal or tubing. Keep ignitor cable dry

5.

Broken ignitor cable

5.

Replace ignitor cable

6.

Bad piezo ignitor

6.

Replace piezo ignitor

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP gas only)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Re- peat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, page 15) or replace ODS/ pilot assembly

7.Replace gas regulator

ODS/pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Safety interlock system has been triggered

4.Equipment shutoff valve not fully open

5.Thermocouple connection loose at con- trol valve

6.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged ODS/pilot

7.Thermocouple damaged

8.Control valve damaged

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Wait one minute for safety interlock sys- tem to reset. Repeat ignition operation

4.Fully open equipment shutoff valve

5.Hand tighten until snug, then tighten 1/4 turn more

6.A) Contact local natural or propane/LP gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 15) or replace ODS/ pilot assembly

7.Replace pilot assembly

8.Replace control valve

For morevisit www..com

107882-01E

Image 17
Contents What to do if YOU Smell GAS Safety Information Installation ManualSafety Information Table of ContentsProduct Identification Product FeaturesUnpacking Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installing Heater to WallPlacing Heater On Mounting Bracket Attaching Mounting Bracket To WallMounting Base Feet to Floor Where required by local code Installing Bottom Mounting ScrewsMounting Heater to Floor Mounting Base Feet to HeaterTypical Inlet Pipe Diameters Connecting to GAS SupplyChecking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Lighting Instructions For Your Safety Read Before LightingOperating Heater Inspecting Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationCleaning Burner Pilot AIR Inlet Cleaning MaintenanceBurner Flame Pattern ODS/PILOT and BurnerService Hints SpecificationsTechnical Service Service PublicationsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at CBN20 CBP20 Illustrated Parts BreakdownKEY Part Number for CBN20 CBP20 Description QTY Parts ListCBN20T, CBP20T CBN30T, CBP30T NJF 8C Accessories Replacement PartsOwners Registration Form For Com Parts Centrals Washer Equipment Co Laporte’s Parts & ServiceWarranty Information