INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must in- stall heater. Follow all local codes.

CHECK GAS TYPE

Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

for propane/LP gas, external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

sediment trap

tee joint

pipe wrench

for natural gas, test gauge connection*

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional CSA design-certified equipment shutoff valve can be purchased from your dealer. See Accessories, page 24.

LOCATING HEATER

WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clear- ances from floor, ceiling, and joining wall.

You can locate heater on the floor, away from a wall. A wall mounting bracket and floor base stand are included with this heater. Determine which method is best for your application.

INSTALLATION

7

Check Gas Type

Installation Items

 

Locating Heater

 

 

 

WARNING: Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

CEILING

36"

6"Minimum Minimum

From Sides Of Heater

Left

Right

Side

Side

2" Minimum To

Top Surface

FLOOROf Carpeting,

Tile Or Other

Combustible

Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content in the air.

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving vehicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 24. If planning to use fan, locate heater near an electrical outlet.

For morevisit www..com

107882-01E

Image 7
Contents What to do if YOU Smell GAS Safety Information Installation ManualSafety Information Table of ContentsLocal Codes Product FeaturesProduct Identification UnpackingConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Locating Heater InstallationInstallation Items Check GAS TypeThermostat Sensing Bulb Installing Heater to WallPlacing Heater On Mounting Bracket Attaching Mounting Bracket To WallMounting Base Feet to Heater Installing Bottom Mounting ScrewsMounting Base Feet to Floor Where required by local code Mounting Heater to FloorTypical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Operating Heater For Your Safety Read Before LightingLighting Instructions Thermostat Control Operation Manual Lighting ProcedureInspecting Heater To Turn OFF GAS To ApplianceODS/PILOT and Burner Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Burner Flame PatternService Publications SpecificationsService Hints Technical ServiceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at CBN20 CBP20 Illustrated Parts BreakdownKEY Part Number for CBN20 CBP20 Description QTY Parts ListCBN20T, CBP20T CBN30T, CBP30T NJF 8C Accessories Replacement PartsOwners Registration Form For Com Parts Centrals Washer Equipment Co Laporte’s Parts & ServiceWarranty Information