OWNER’S MANUAL
INSTALLATION
NOTICE: A qualified service per- son must install heater. Follow all local codes.
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION ITEMS
Before installing heater, make sure you have the items listed below.
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•manual shutoff valve *
•ground joint union
•test gauge connection * (see Figure 13, page 10)
•sediment trap
•tee joint
•pipe wrench
WARNING: Never install the heater
•in a bedroom or a bathroom
•in a recreational vehicle
•where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
•as a fireplace insert
•in high traffic areas
•in windy or drafty areas
CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.
IMPORTANT:
CAUTION: If you install the heater in a home garage
•heater pilot and burner must be at least 18 inches above floor
•locate heater where moving ve- hicle will not hit it
For convenience and efficiency, install heater
•where there is easy access for operation, inspection, and service
•in coldest part of room
An optional fan kit is available from your dealer. See Accessories, page 19. If plan- ning to use fan, locate heater near an electri- cal outlet.
*An A.G.A.
LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING: Maintain the mini- mum clearances shown in Figure
4.If you can, provide greater clear- ances from floor, ceiling, and join- ing wall.
You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 19.
CEILING
36"
Minimum
6" Minimum
From Sides Of
Heater
Left | Right |
Side | Side |
| 3" Minimum To Top Surface |
| Of Carpeting, Tile Or Other |
FLOOR | Combustible Material |
Figure 4 - Mounting Clearances As Viewed From Front of Heater
Continued
104190 | 7 |