Desa Tech CGN20TA Attaching Mounting Bracket To Wall, Placing Heater On Mounting Bracket

Page 9

OWNER’S MANUAL

INSTALLATION

Continued

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 9.

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings.

IMPORTANT: Do not hammer key!

For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Figure 10 - Popping Open Anchor Wings For Thin Walls

5.Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Placing Heater On Mounting Bracket

1.Locate two horizontal slots on back panel of heater.

2.Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Horizontal Slots

Installing Bottom Mounting Screws

1.Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 12).

2.Mark screw locations on wall.

3.Remove heater from mounting bracket.

4.If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 un- der Attaching To Wall Anchor Method, column 1.

If installing bottom mounting screw into wall stud, drill holes at marked lo- cations using 9/64" drill bit.

5.Replace heater onto mounting bracket.

6.Place spacers between bottom mount- ing holes and wall anchor or drilled hole.

7.Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.

8.Tighten both screws until heater is firmly secured to wall. Do not over tighten.

Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 10 and 11).

Figure 9 - Folding Anchor

Stand-Out

Tab

Mounting Bracket (attached to wall)

Figure 11 - Mounting Heater Onto

Mounting Bracket

Figure 12 - Installing Bottom Mounting

Screws

104190

9

Image 9
Contents What to do if YOU Smell GAS Blue Flame VENT-FREE Natural GAS HeaterCGN20TA Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installing Heater to WallInstalling Bottom Mounting Screws Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Typical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Heater GAS Connections Pressure Testing GAS Supply Piping SystemChecking GAS Connections Test Pressures In Excess Of 1/2Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceInspecting Burner Manual Lighting ProcedureThermostat Control Operation Pilot Flame PatternObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Service Publications Replacement Parts Cleaning and Maintenance SpecificationsTechnical Service Service HintsFBD Parts CentralsAccessories FAN Kits GA3100A and GA3200TAManual Shutoff CGN20TA Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListCGN20TA 104190 Warranty Information