Dayton instruction manual Specifications for Model 3VH18A, Specifications for Model 3VH19A

Page 4

Dayton Operating Instructions and Parts Manual

3VH18A and 3VH19A

Dayton® Propane and Natural Gas

Construction Heaters

Specifications for Model 3VH18A

Output

 

Minimum Fuel

Maximum Fuel

Size

Weight

Rating Btu/Hr

Fuel

Consumption

Consumption

L x W x H (Inches)

(pounds)

40,000 to 100,000

Propane

0.44 Gallons/Hour

1.1

Gallons/Hour

16 x 16 x 35

30

(Heater)

 

Vapor Only

1.86 Pounds/Hour

4.7

Pounds/Hour

18 x 18 x 36

35

(Shipping)

 

 

 

 

 

 

Maximum Supply

Minimum Supply

 

Min. Temperature

Manifold Pressure

Ignitor

Pressure to Regulator

Pressure to Regulator

Surrounding Air

 

(Inches of Water Column)

Gap (Inches)

200 psi

20 psi (for purposes

-20ºF (-29ºC)

 

13.3

(High)

 

0.15

 

 

of input adjustment)

 

 

25.6

(Low)

 

 

 

Specifications for Model 3VH19A

Output

 

Minimum Fuel

Maximum Fuel

Size

Weight

Rating Btu/Hr

Fuel

Consumption

Consumption

L x W x H (Inches)

(pounds)

50,000 to 100,000

Natural Gas

48 scfh

100 scfh

 

16 x 16 x 35

30

(Heater)

 

Only

 

 

 

18 x 18 x 36

35

(Shipping)

 

 

 

 

 

 

Maximum Supply

Minimum Supply

 

Min. Temperature

Manifold Pressure

Ignitor

Pressure to Regulator

Pressure to Regulator

Surrounding Air

(Inches of Water Column)

Gap (Inches)

14 inches w.c.

6 inches w.c. (for

-20ºF (-29ºC)

2.7

(High)

0.15

 

 

purposes of input

 

3.2

(Low)

 

 

 

adjustment

 

 

 

 

 

 

Propane Supply for Model 3VH18A

You must provide propane gas and propane tank(s).

Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA B149.2. Your local library or fire department will have this booklet.

The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount.

1.The amount of propane gas in tank(s)

2.The temperature of tank(s)

The chart below shows the minimum number of 100-pound tanks needed to run the heater. Connect tanks together with a manifold. Do not operate this product with any tank smaller than 100 pounds.

Average Temperature (ºF)

Number of

at Tank Location

Tanks (100-lbs)

60°

2

40°

2

32°

2

20°

2

10°

3

0°

3

Less gas is vaporized at lower tempera- tures. Two or more 100-pound tanks or one larger tank may be needed in colder weather. Your local propane gas dealer will help you select the proper supply system.

4

Image 4 Contents
Description UnpackingGeneral Safety Information Dayton Propane and Natural Gas Construction HeatersTheory of Operation Product IdentificationFuel System Ignition SystemSpecifications for Model 3VH19A Specifications for Model 3VH18APropane Supply for Model 3VH18A Installation Natural Gas Supply for Model 3VH19AVentilation Propane Model 3VH18AOperation To Start HeaterTroubleshooting Chart For Replacement Parts, call Replacement Parts List 3VH18A and 3VH19A 3VH18A and 3VH19A Not a UPC