Dayton 3VH18A, 3VH19A instruction manual Troubleshooting Chart

Page 7

Dayton Operating Instructions and Parts Manual

Model 3VH18A - Propane

Model 3VH19A - Natural Gas

Troubleshooting Chart

 

 

 

Never attempt to service heater while it is connected to gas supply, operating, or hot. Severe burns can

 

 

 

 

 

 

 

 

occur.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

Possible Cause(s)

Corrective Action

 

 

 

 

 

 

 

 

Burner fails to light

1. (Propane model only) Propane supply

1. (Propane model only) Open propane

 

 

 

 

 

valve closed on propane tank(s)

supply valve slowly

 

 

 

 

 

2. (Propane model only) Excess flow check

2. (Propane model only) Close propane

 

 

 

 

 

valve closed

supply valve on propane tank and

 

 

 

 

 

 

reopen slowly

 

 

 

 

 

3. Blockage in burner orifice

3. Replace burner orifice

 

 

 

 

 

4. Piezo ignition system not sparking

4. Assure ignitor electrode gap is .15".

 

 

 

 

 

 

Check wire lead for damage. Replace

 

 

 

 

 

 

piezo ignitor and/or ignitor electrode as

 

 

 

 

 

 

necessary

 

 

 

 

 

 

Burner lights but goes out when automatic

1. Not enough warm-up time

1. Relight, hold automatic control valve

 

control valve button is released

 

button in for 45 seconds

 

 

 

 

 

2. Low gas pressure

2. (Propane model only) Check propane

 

 

 

 

 

 

tank(s) for proper gas supply

 

 

 

 

 

 

(Natural gas model only) Check natural

 

 

 

 

 

 

gas supply

 

 

 

 

 

3. Thermocouple loose or needs to be

3. Tighten connection or replace thermo-

 

 

 

 

 

replaced

couple

 

 

 

 

 

4. Automatic control valve needs to be

4. Replace automatic control valve

 

 

 

 

 

replaced

 

 

 

 

 

 

 

Burn rate is low, emitter does not glow

1. Burner control is on Low

1. Slightly depress control knob and rotate

 

 

 

 

 

 

counterclockwise to the HIGH position

 

 

 

 

 

2. Blockage in burner orifice

2. Replace burner orifice

 

 

 

 

 

3. Low gas pressure

3. Check gas supply; check regulator

 

 

 

 

 

 

output

 

 

 

 

 

4. Low fuel supply

4. Consult gas supplier

 

 

 

 

 

 

 

 

Flames are extremely high and coming from emitter

1.(Natural gas model only) Unit has been connected to propane gas instead of natural gas

1.(Natural gas model only) Check gas source and replace with natural gas supply

®

7

Version B - For Reduction

G016.J

Image 7 Contents
Unpacking DescriptionDayton Propane and Natural Gas Construction Heaters General Safety Information Ignition System Theory of Operation Product Identification Fuel SystemSpecifications for Model 3VH19A Specifications for Model 3VH18APropane Supply for Model 3VH18A Propane Model 3VH18A InstallationNatural Gas Supply for Model 3VH19A VentilationTo Start Heater OperationTroubleshooting Chart For Replacement Parts, call Replacement Parts List 3VH18A and 3VH19A 3VH18A and 3VH19A Not a UPC