FMI FVF18P, FVF24P, FVF30P Product Features, Product Identification, Local Codes, Unpacking

Page 3

OWNER’S MANUAL

SAFETY

INFORMATION

Continued

12.This heater needs fresh, outside air ven- tilation to run properly. This heater has an oxygen depletion sensor (ODS) pi- lot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Trouble- shooting, pages 17 through 19.

13.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

14.Do not use this heater to cook food or burn paper or other objects.

15.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room heater and to replace any part of the control system and any gas control which has been under water.

16.Do not operate heater if any log is bro- ken. Do not operate heater if a log is chipped (dime-sized or larger).

17.Turn heater off and let cool before ser- vicing. Only a qualified service person should service and repair heater.

18.Operating heater above elevations of 4,500 feet could cause pilot outage.

19.Provide adequate clearances around air openings.

PRODUCT

FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and ap- proved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANSI Z21.60) product by opening the flue damper.

SAFETY PILOT

PRODUCT IDENTIFICATION

One-Piece

Log Set

Burner

Piezo Ignitor

Base Assembly

Control Knob

Figure 1 - Heat Majic™ Log Set

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

UNPACKING

CAUTION: Do not remove the data plates from the grate assem- bly. The data plates contain impor- tant product information.

1.Remove logs and heater base assem- bly from carton. Note: Do not pick up heater base assembly by the burner. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging ap- plied to logs and heater for shipment.

3.Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater.

105192

3

Image 3
Contents 18, 24 and 30 Variable OWNER’S Operation and Installation ManualAlso DESIGN-CERTIFIED AS a Vented Decorative Appliance What to do if YOU Smell GASUnvented PROPANE/LP GAS LOG Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingInstallation InstallationCheck GAS Type If Using Mantel If Not Using MantelMinimum Noncombustible Material Clearances Determining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesChimney Minimum Permanent Height ft Flue Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Safety informationAttaching Flexible Gas Hose to Heater Gas Regulator Installation Items NeededExternal Regulator With Vent Pointing Down Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Heat Majic One- Piece Log Set Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Inspecting Burners Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at TopCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceService Hints Technical ServiceReplacement Parts AccessoriesSpecifications Illustrated Parts Breakdown Heat Majic FVF18P FVF24P FVF30PODS Pilot FVF18P FVF24P FVF30P Parts ListWarranty Information

FVF24P, FVF18P, FVF30P specifications

The FMI FVF series of fireplaces, which includes models FVF30P, FVF18P, and FVF24P, represents a blend of contemporary design and advanced heating technology. Each model is designed to provide efficient and aesthetic warmth to any space, making them ideal for modern homes and commercial settings.

The FVF30P is the largest in the series, featuring a striking glass front that allows for an unobstructed view of the flames. Its generous heating capability makes it suitable for larger rooms, ensuring that warmth permeates every corner. Equipped with a powerful blower system, this model enhances heat distribution, making it an ideal choice for those seeking both efficiency and aesthetics.

The FVF18P, in contrast, is designed for smaller spaces, combining compact dimensions with impressive heating performance. Its sleek design allows it to fit seamlessly into any decor, while still providing the ambiance of a traditional fireplace. With advanced technology that ensures optimal combustion, this model minimizes emissions and maximizes efficiency, meeting stringent environmental standards.

The FVF24P stands as a middle ground between the two, offering versatile installation options and a balanced heating output. This model also boasts an elegant glass front that enhances visual appeal. Like its counterparts, the FVF24P incorporates modern technologies that ensure a clean burn, significantly reducing fuel consumption while maximizing output.

All models include advanced ignition systems, such as electronic ignition, making startup simple and convenient. Each unit is designed with ease of maintenance in mind, featuring removable panels and accessible components that simplify cleaning. Moreover, these fireplaces offer various finishes and trim options, allowing customization to match individual tastes and home designs.

Safety is another hallmark of the FMI FVF series. Each fireplace is equipped with safety features such as a tempered glass front, automatic shut-off systems, and optional heat management systems to prevent overheating. Customer satisfaction is further ensured through generous warranties and exceptional after-sale support provided by FMI.

In conclusion, the FMI FVF30P, FVF18P, and FVF24P models stand out in the market due to their combination of aesthetic appeal, cutting-edge technology, and commitment to efficiency and safety, making them an excellent investment for anyone looking to enhance their living space with modern warmth.