VI. PERIODIC PREVENTIVE MAINTENANCE

NOTE: Periodic inspection and preventive maintenance of your total heating system is important for efficient and safe operation. Your heating dealer should perform humidifier service at the same time.

All models are equipped with an in-line water strainer and orifice as shown below. These parts should be inspected and cleaned periodically to assure continued proper unit performance.

INSPECTION AND SERVICE INSTRUCTIONS

1.Disconnect electrical power to the furnace and shut off water supply.

2.Disconnect the water line at the inlet compression nut.

3.Remove the in-line strainer from inside the inlet fitting by using a small nail or wire.

4.Flush the in-line strainer clean or replace with a new strainer, Service Part No. SRA00859.

5.Replace the in-line strainer and reconnect the inlet water line.

(Double Wrench To Prevent Leaking.)

6.Disconnect the water line at the outlet compression nut.

7.Remove the orifice from the copper or plastic tube and make sure this small opening is unplugged.

8.Replace the orifice and reconnect the outlet water line.

(Double Wrench To Prevent Leaking.)

9.Turn on water supply @ Saddle Valve and reconnect electrical power to the furnace.

- 8 -

Image 10
Contents Humidifiers Table of Contents Introduction How Your Humidifier OperatesYour Humidifier Important Notes About Your HumidifierII. Operating Instructions Operation GuideDetermine the outdoor temperature % Relative Humidity Guide Outside Temperature Recommended RH Outdoor-Indoor Relative HumidityIII . Effect of Water Characteristics Additional InformationIV. Annual Maintenance Annual Summer ShutdownVI. Periodic Preventive Maintenance Inspection and Service InstructionsSet humidifier or control to its original position Humidifier Model *HUMD500A Limited Warranty Humidifier HUMD0200A, 300A, 500AService and Humidifier PAD Replacement Record