MAINTENANCE INSTRUCTIONS for HUMIDIFIER MODELS *HUMD200A, *HUMD300A

CAUTION! Sudden operation may cause personal injury or property damage. Turn humidistat or humidifier control to “OFF” or lowest setting before servicing.

 

 

 

 

4

 

6

5

 

 

1

3

 

8

 

 

 

 

 

 

1.

Front Cover

 

 

 

2. Drain Hose

 

 

 

3. Bypass Damper

 

 

 

4. Humidifier Pad

 

 

 

 

Assembly

 

 

 

5.

Distribution Tray

 

 

 

6.

”V” Notches

 

 

 

7.

1. Front C

 

 

 

Humidifier Pad

 

 

 

8.

2. Drain H

 

 

 

Scale Control Insert

 

2

7

 

3. Bypass

 

 

4. Water P

 

 

 

 

90-820

 

 

 

Assem

 

 

 

 

5 Distribu

1.Note humidifier control setting and turn dial to the “OFF” position.

2.Turn off water supply.

3.At the side of the unit opposite the airflow duct pull front cover (1) off holding with both hands and set aside.

4.Pull out the humidifier pad assembly (4) by grasping at top and tipping out.

5.Remove the plastic distribution tray (5) from the humidifier pad assembly by unsnapping the plastic holding strips from the tabs at the end of the tray. Lightly scrape out any mineral deposits and clean the “V” notches (6), but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance. If coating is removed replace distribution tray.

6.Slide the humidifier pad (7) out from the plastic Scale Control Insert (8). Clean the insert frame by twisting and flexing it to loosen the calcium deposits, or use a putty knife. Replace the humidifier Pad annually with a #BAYPAD01A1010A humidifier pad for Model HUMD200A and #BAYPAD02A1310A humidifier pad for Model HUMD300A. Slide the pad back into the insert frame with the colored spot up and snap the distributor tray back into place.

7.Re-install the humidifier pad assembly into the unit by fitting its drain into the round receptacle at the base of the unit. Push the assembly in at the top against the retaining ribs that will hold it in place. Push the end of the feed tube back firmly into the nozzle and replace the front cover.

8.Remove the drain hose (2) from the bottom of the unit and bend and flex it to loosen the internal mineral deposits. Then flush it with water under pressure and slip it back onto the black drain fitting.

9.Turn on water supply @ saddle valve.

10.Check system operation:

Manual Humidifier Control: Turn up humidifier control to highest setting and make sure the furnace and blower are operating. Humidifier will operate if RH is less than 50%. Automatic Humidifier Control: Check system operation by setting the knob to “Test.” With furnace and blower operating humidifier will operate for one minute.

11.Set humidifier or control to its original position.

*HUMD200A, *HUMD300A *MAY BE “A” OR “T”

- 9 -

Image 11
Contents Humidifiers Table of Contents How Your Humidifier Operates IntroductionImportant Notes About Your Humidifier Your HumidifierOperation Guide II. Operating Instructions% Relative Humidity Guide Determine the outdoor temperatureOutdoor-Indoor Relative Humidity Outside Temperature Recommended RH Additional Information III . Effect of Water CharacteristicsAnnual Summer Shutdown IV. Annual MaintenanceInspection and Service Instructions VI. Periodic Preventive MaintenanceSet humidifier or control to its original position Humidifier Model *HUMD500A HUMD0200A, 300A, 500A Limited Warranty HumidifierService and Humidifier PAD Replacement Record