American Standard 300A, 500A Outside Temperature Recommended RH, Outdoor-Indoor Relative Humidity

Page 7

To check the humidifier’s operation, note the current setting and set the Automatic Humidifier Control to the test mode when the furnace blower motor is operating. Water will flow into the humidifier for 1 minute and then it will turn off. This insures the unit is operating properly. Do not leave the control in the test mode as it will not operate. Reset the control to it’s original setting.

Model HUMD200A with Manual Mode:

(Automatic Humidifier Control – see pg 3)

Your new Humidifier is controlled by a humidifier control installed either in the living area (typically near the thermostat) or in the cold air return. It is important to anticipate a drop in outdoor temperature and reduce the setting accordingly to avoid excessive condensation. For example, with an outdoor temperature of 20°F the correct setting will be 35% relative humidity. If the temperature is expected to fall to 0°F that evening, then merely reduce the setting to 25% several hours prior to the temperature change.

The recommended settings on the humidifier control are based on years of research (see Table 3) and experience as to what is best for the average home. These settings represent a compromise between RH levels that would be most desirable for comfort reasons and humidity levels that are suitable for protection of your home. For example, a wintertime indoor RH of 50% may be considered ideal by some, but unfortunately, it probably would result in damage to your home. Observance of the recommended RH levels on your humidistat, therefore, is an important safeguard. Condensation of water on inside windows in the form of fogging or frost is usually an indication of too high relative humidities. This same condensation can take place in other areas in your home with the possibility of damage resulting.

TABLE 3 – Outdoor-Indoor Relative Humidity

Outside Temperature

Recommended RH

+40°F

45%

+30°F

40%

+20°F

35%

+10°F

30%

0°F

25%

– 10°F

20%

– 20°F

15%

 

 

The humidistat is a precision instrument that can be used to determine the RH accurately in your home during the winter. Turn the dial to the lower setting, then reverse the dial direction slowly until a “click” is heard. At this point, read the RH on the dial. This will be very close to the actual RH in your home.

- 5 -

Image 7
Contents Humidifiers Table of Contents How Your Humidifier Operates Introduction Important Notes About Your Humidifier Your HumidifierOperation Guide II. Operating Instructions% Relative Humidity Guide Determine the outdoor temperatureOutdoor-Indoor Relative Humidity Outside Temperature Recommended RHAdditional Information III . Effect of Water CharacteristicsAnnual Summer Shutdown IV. Annual MaintenanceInspection and Service Instructions VI. Periodic Preventive MaintenanceSet humidifier or control to its original position Humidifier Model *HUMD500A HUMD0200A, 300A, 500A Limited Warranty HumidifierService and Humidifier PAD Replacement Record