Specifications

Environmental Specifications

Mode

Temperature

Humidity

Operating

0 °C to 40 °C (32 °F to 104 °F)

10 to 90% RH (no condensation

 

 

allowed)

Storage

-20 °C to 70 °C (-4 °F to 158 °F)

 

 

 

Electrical Specifications

 

Input voltage

100 to 240V AC (50/60 Hz)

 

 

 

 

Input current

0.5 A (maximal)

 

 

 

 

 

 

Available Output Power (Maximum)

16.8 W

 

 

 

 

Nominal Output Voltage

48V DC

 

 

 

Ethernet Interface

 

 

 

 

 

Input (Data In): Ethernet 10/100Base-T

RJ45 female socket

 

 

 

 

Output (Data & Power Out):

RJ45 female socket, with DC

 

Ethernet 10/100Base-T, plus 48 VDC

voltage on wire pairs 4-5 and 7-8.