Axis Communications AXIS T8120 manual Troubleshooting, Symptom Corrective Steps

Models: AXIS T8120

1 10
Download 10 pages 8.94 Kb
Page 8
Image 8

Page 8

AXIS T8120 Installation Guide

Troubleshooting

Symptom

Corrective Steps

Midspan does not power up

1.

Verify that an approved power cord is used.

 

2.

Verify that the voltage at the power inlet is

 

 

between 100 and 240V AC.

 

3.

Remove and re-apply power to the device and

 

 

check the indicators during power up sequence.

A port indicator is not lit

1.

The Midspan did not detect a device and

and the Midspan does not

 

therefore the port is not enabled.

operate

2.

Verify that the device is designed for PoE

 

 

operation

 

3.

Verify that you are using a standard Category 5/

 

 

5e/6, straight-wired cable, with four pairs

 

4.

If there is a connected external power splitter,

 

 

replace it to verify that it is functioning properly

 

5.

Ensure that the input Ethernet cable is connected

 

 

to the Data In port

 

6.

Verify that the device is connected to the Data &

 

 

Power port.

 

7.

Try to reconnect the same device into a different

 

 

Midspan. If it works, there is probably a faulty

 

 

port or RJ45 connection.

 

8.

Verify that there is no short over any of the

 

 

twisted pair cables or over the RJ45 connectors.

The end device operates, but

1.

Verify that the port indicator on the front panel is

there is no data link

 

continuously lit.

 

2.

If an external power splitter is in use, replace it

 

 

with a known-good splitter.

 

3.

Verify that for this link, you are using standard

 

 

UTP/FTP Category 5 straight (non-crossover)

 

 

cabling, with all four pairs.

 

4.

Verify that the Ethernet cable length is less than

 

 

100 meters from the Ethernet source to the load/

 

 

remote terminal.

 

5.

Try to reconnect the same device into a different

 

 

Midspan. If it works, there is probably a faulty

 

 

port or RJ45 connection.

Page 8
Image 8
Axis Communications AXIS T8120 manual Troubleshooting, Symptom Corrective Steps