HUMIDIFIER CONTROL:
Humidifiers controlled by the Humidifier Control require no control adjustment. Shut off the water supply to the humidifier by closing the saddle valve.
MANUAL HUMIDISTAT:
For humidifiers controlled by a manual humidistat, simply turn the humidistat to the “Off” position. Shut off the water supply to the humidifier by closing the saddle valve.
VIII. PERIODIC PREVENTATIVE MAINTENANCE
NOTE: Periodic inspection and preventive maintenance of your total heating system is important for efficient and safe operation. Your heating contractor should include humidifier service at the same time.
All models, except No’s. 448 and 445, are equipped with an
INSPECTION AND SERVICE INSTRUCTIONS
1.Disconnect electrical power to the furnace and shut off water supply.
2.Disconnect the water line at the inlet compression nut.
3.Remove the
4.Flush the
5.Replace the
(Double Wrench To Prevent Leaking.)
6.Disconnect the water line at the outlet compression nut.
7.For units with plastic feed tubes, inspect the tube by gently flexing it and looking for cracks or signs of wear. Replace tube if it is cracked, brittle or has been damaged.
8.Remove the orifice from the copper or plastic tube and make sure this small opening is unplugged.
9.Replace the orifice and reconnect the outlet water line.
(Double Wrench To Prevent Leaking.)
10.Remove the drain hose from the bottom of the unit and flex it to remove any mineral deposits or blockage. Flush the hose with water under pressure to clear it of any debris. Make sure the drain hose has a constant downward slope and is not flattened or blocked.
11.Turn on water supply and reconnect electrical power to the furnace.
- 9 -