Aprilaire 110 owner manual Property damage. Turn, Setting before servicing

Page 15
1. Cover Knob
2. Top Cover
3. Feed Nozzle
4. Distribution Tray
5. Metal Frame
MODELS
440, 445 & 448

MAINTENANCE INSTRUCTIONS for

APRILAIRE HUMIDIFIER MODEL 440

CAUTION! Sudden operation

 

 

5

may cause personal injury or

 

2

3

property damage. Turn

 

4

 

 

humidistat to “off” or lowest

 

 

setting before servicing.

1

 

1

1. Note humidistat setting and turn

 

 

 

 

 

 

dial to the “Off” position.

 

 

 

2. Remove two aluminum knobs (1), swing up and remove top cover (2) from humidifier.

3. Place finger under plastic water nozzle (3) at top of water distribution tray (4). Lift up to pop

outlet loose from hole and notch in distribution tray.

4. Tip forward and lift the complete plastic framed evaporative assembly out of the humidifier.

5. To remove plastic water distribution tray from evaporative assembly, push down on pan and out on plastic frame (Scale Control Insert). Follow instructions below depending upon the type of distribution tray in your humidifier.

For trays with a synthetic fabric liner: Lightly scrape out or brush off any mineral deposits, being careful not to stretch or loosen the synthetic fabric liner. Soaking the tray in vinegar or a lime-removing agent is helpful when trying to remove stubborn mineral deposits.

For trays with granular coating: Do not scrape off the granular coating, but lightly scrape out any mineral deposits and clean the “V” notches. This textured surface helps ensure even water flow for maximum performance. See page 3 if removed.

6.Remove Water Panel evaporator from Scale Control Insert and clean Insert by flexing or using putty knife. Inspect Water Panel evaporator (Stock No. 12) and replace if necessary with colored spot up. Snap plastic water distribution tray back in place.

7.For units with plastic feed tubes, inspect the tube by gently flexing it and looking for cracks or signs of wear. Replace tube if it is cracked, brittle or has been damaged.

8.Reinstall evaporative section in the humidifier with notch and hole in plastic water distribution pan toward you. Pop nozzle fitting on end of feed tube into plastic water distribution pan.

9.To reinstall top cover, hook back under lip of metal frame (5), drop in place and tighten two aluminum knobs.

10.Remove drain hose and flush with water under pressure. Mineral deposits in hose may be loosened by flexing hose.

11.Reattach drain hose. Make sure the drain hose has a constant downward slope and is not flattened or blocked.

12.Turn humidistat to highest setting and make sure the furnace blower is operating. Humidifier will operate if RH is less than 50%.

13.Set humidistat to its original position.

MODEL 440

- 13 -

Image 15
Contents Humidifiers Table of Contents Introduction Principle of Operation Page Operation Guide Automatic Mode Manual Mode-see pgDial % Relative Humidity GuideOutdoor-Indoor Relative Humidity Manual Mode Automatic Mode see pgIV. Additional INFORMATION- ALL Models Effect of Water CharacteristicsVII. Annual Summer Shutdown VI. Annual MaintenanceVIII. Periodic Preventative Maintenance Models Clip Inlet Grille Property damage. Turn Setting before servicing448 Models 445-448 Reservoir Pump Sections Set humidistat or Control to its original position Front Cover Base Evaporative Assembly Thank you