Aprilaire 110 owner manual 448

Page 16

448

MAINTENANCE INSTRUCTIONS for APRILAIRE HUMIDIFIER MODELS 445-448

MODELS 445-

WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing.

1.Note humidistat or Humidifier Control setting and turn dial to the “Off” position.

 

 

5

 

2

3

 

4

 

 

1

 

1

 

 

2. Disconnect electrical power and turn

 

off water supply.

MODELS

3. Remove two aluminum knobs (1),

440, 445 & 448

swing up and remove top cover (2)

 

from humidifier.

 

4.Place finger under plastic water nozzle (3) at top of water distribution tray (4). Lift up to pop outlet loose from hole and notch in distribution tray.

5.Tip forward and lift the complete plastic framed evaporative section out of the humidifier.

1.Cover Knob

2.Top Cover

3.Feed Nozzle

4.Distribution Tray

5.Metal Frame

6.To remove plastic water distribution tray from evaporative

section, push down on pan and out on plastic frame (Scale Control Insert). Follow instructions below depending upon the type of distribution tray in your humidifier. For trays with a synthetic fabric liner: Lightly scrape out or brush off any mineral deposits, being careful not to stretch or loosen the synthetic fabric liner. Soaking the tray in vinegar or a lime-removing agent is helpful when trying to remove stubborn mineral deposits.

For trays with granular coating: Do not scrape off the granular coating, but lightly scrape out any mineral deposits and clean the “V” notches. This textured surface helps ensure even water flow for maximum performance. See page 3 if removed.

7.Remove Water Panel evaporator and Scale Control Insert. Remove Water Panel evaporator from Insert and clean insert by flexing or using putty knife. Inspect Water Panel evaporator and replace with a new Water Panel evaporator, if necessary, with colored spot up.

8.Re-install water distribution tray. Reinstall evaporative section in the humidifier, with notch and hole in distribution tray toward you. Pop hose fitting on end of feed tube into distribution tray.

9.See page 15 for reservoir and pump cleaning.

- 14 -

Image 16
Contents Humidifiers Table of Contents Introduction Principle of Operation Page Automatic Mode Manual Mode-see pg Operation Guide% Relative Humidity Guide DialManual Mode Automatic Mode see pg Outdoor-Indoor Relative HumidityEffect of Water Characteristics IV. Additional INFORMATION- ALL ModelsVI. Annual Maintenance VII. Annual Summer ShutdownVIII. Periodic Preventative Maintenance Models Clip Inlet Grille Setting before servicing Property damage. Turn448 Models 445-448 Reservoir Pump Sections Set humidistat or Control to its original position Front Cover Base Evaporative Assembly Thank you