Bionaire W15 manual Maintenance Weekly, Maintenance Daily, Instructions Maintenance and Cleaning

Page 11

10

 

.reservoir

 

the disinfect to beginning before solution vinegar white

 

the and scale remove to water warm clean with Rinse

.3

.scale remove to base entire out

 

wipe and vinegar white undiluted with cloth a Dampen

 

.brush soft a with surfaces interior all cleaning minutes,

 

20 for stand solution Let

.®Bionaire by Away™ Clean

 

use or vinegar, white

undiluted of cup ounce-8

 

one with base the filling partially by base the Clean .2

 

.above 4-1 steps Repeat

.1

 

Scale: Remove

 

MAINTENANCE WEEKLY

.humidifier the off turn windows, or walls on forms moisture If

.6

.water tap cool with reservoirs water the

 

Refill .housing humidifier the then and holder wick the

 

replace base, the into back filters air and wick the Put

.5

 

.towel paper or cloth

 

clean a with dry and clean Wipe .dirt and sediment

 

any remove to thoroughly reservoirs water and base

 

the rinse and drain then filters, air and filter, wick the

 

remove sink, the to reservoirs water and base the Carry

.4

 

.thumbscrews

 

4 the unscrewing by holder wick the Remove .3

.housing humidifier the and reservoirs water the off Lift

.2

.outlet electrical the from unit the unplug

 

and position OFF the to Mode the set cleaning, Before

.1

 

MAINTENANCE DAILY

.reservoir humidifier’s the within water the in grow to able

be may organisms-micro instructions, maintenance and

care recommended the follow not do you if addition, In

.use in when attention requires and

appliance, electrical an is this that note Please .guidelines

maintenance and care operation, the specifically carefully,

instructions all follow misuse, product avoid and humidifier

the from benefit most

the get To .air indoor heated

dry, to moisture adding by comfort provide Humidifiers

INSTRUCTIONS MAINTENANCE AND CLEANING

L’humidificateur demandera environ 30 minutes avant d’atteindre son rendement maximum.Vous pouvez obtenir votre modèle de filtre (BWF1500) en appelant le 1 800 253- 2764 en Amérique du Nord ou en visitant votre détaillant le plus près.

REMPLACEMENT DES FILTRES À AIR

Dans le cadre d’une utilisation normale, les particules dans l’air viendront à se piéger dans les deux filtres à air. Pour remplacer les deux filtres à air, suivez les mêmes directives que ci-dessus. Les filtres à air se trouvent à côté des grilles d’entrée. Remplacez les filtres à air à chaque période de 4 à 6 mois ou lorsqu’ils brunissent.Vous pouvez obtenir votre modèle de filtre à air (BAPF1500) en appelant le 1 800 253- 2764 en Amérique du Nord ou en visitant votre détaillant le plus près.

DIRECTIVES DE NETTOYAGE ET D’ENTRETIEN

Les humidificateurs rendent votre environnement plus confortable en ajoutant de l’humidité dans l’air sec et chaud de la pièce. Pour profiter pleinement des avantages fournis par l’humidificateur et pour bien utiliser le produit, suivez soigneusement toutes ces directives, plus précisément les lignes directrices d’usage, de soin et d’entretien. Veuillez noter que l’humidificateur est un appareil électrique et qu’il nécessite votre attention lorsqu’il est en marche. De plus, si vous manquez d’observer les directives de soin et d’entretien, des micro-organismes pourraient venir à croître dans l’eau du réservoir de l’humidificateur.

ENTRETIEN QUOTIDIEN

1.Avant de commencer le nettoyage, réglez l’appareil en mode d’arrêt (« OFF ») et débranchez-le de la prise de courant.

2.Soulevez les réservoirs d’eau et la boîtier de l’humidificateur.

3.Retirez le porte-filtre en dévissant les quatre vis.

4.Transportez la base et les réservoirs jusqu’à l’évier, retirez le filtre à mèche et les filtres à air, videz et rincez à fond la base et les réservoirs pour éliminer toute saleté et tout sédiment. Essuyez-les avec un chiffon propre ou un essuie-tout.

5.Remettez le filtre à mèche et les filtres à air dans la base, remettez le porte-filtre en place. Remettez en place le boîtier de l’humidificateur. Remplissez les réservoirs d’eau froide du robinet.

6.Si de l’humidité vient à se former sur les murs ou fenêtres, arrêtez l’humidificateur.

10

Image 11
Contents Leaflet Instruction Without humidifier refill to attempt not Do Warning Safeguards ImportantMesures DE Sécurité Importantes Page Directives PRÉ-UTILISATION This of Purpose Safety the Defeat not doInformation Safety Consumer Comment Fonctionne L’HUMIDIFICATEUR À Buée FroideRemplissage DU Réservoir D’EAU Reservoir Water the FillingOnly USE First While minute Every Check Safety CommunicationPremier Usage Seulement Once at unit 1 than more SynchronizeRemote with Operation Humidistat Opération Manuelle Avec TélécommandeUsage DE L’HUMIDISTAT Avec Télécommande Remote Without Operation UnitFunction Timer Usage DE L’APPAREIL Sans TélécommandeOn Unit Turn To Timer Using OFF Unit Turn To Timer UsingRemote Remplacement DU Filtre À Mèche ET À AIRFilter AIR and Wick the Replacing Filters AIR the Replacing Remplacement DES Filtres À AIR Maintenance WeeklyMaintenance Daily Instructions Maintenance and CleaningHumidifier Mist Cool your for Shooting Trouble Reservoir Disinfect Instructions ServiceDirectives DE Service Instructions StorageReference Future for Number this Keep Call Please SERVICE, Warranty forWarranty Garantie

W15 specifications

The Bionaire W15 is a state-of-the-art air purifier designed to enhance indoor air quality through advanced filtration technology. This model is ideal for those seeking an efficient solution to combat allergens, dust, and unpleasant odors in their living spaces.

One of the main features of the Bionaire W15 is its multi-stage filtration system. The purifier is equipped with a HEPA filter, which effectively captures up to 99.97% of airborne particles, including pollen, pet dander, and smoke. This is particularly beneficial for allergy sufferers and individuals with respiratory conditions, as it can significantly reduce irritants in the air. Additionally, the W15 includes a pre-filter that captures larger particles, extending the life of the HEPA filter and enhancing overall performance.

Another notable technology integrated into the Bionaire W15 is its activated carbon filter. This component works to neutralize odors from cooking, pets, and smoke by adsorbing volatile organic compounds (VOCs) and unpleasant smells. This feature is especially useful for maintaining a fresh-smelling home environment, making it feel more inviting and comfortable.

The W15 is also designed with user convenience in mind. It features multiple fan speeds, allowing users to customize air purification settings according to their needs. Whether it’s a quiet operation for nighttime use or a higher speed for quick air cleaning during the day, the W15 can adapt seamlessly to different scenarios.

In terms of design, the Bionaire W15 boasts a sleek and modern aesthetic that fits well in any room decor. Its compact size allows for easy placement on a tabletop, shelf, or even on the floor without taking up too much space. Additionally, the purifier operates quietly, ensuring it won’t disturb daily activities or sleep, making it perfect for bedrooms and living areas.

The Bionaire W15 also includes a filter replacement indicator. This helpful feature alerts users when it’s time to change filters, ensuring optimal performance and air quality at all times. The ease of maintenance contributes to the overall user-friendly experience of the product.

Overall, the Bionaire W15 stands out as a reliable air purifier that combines advanced filtration technologies with user-oriented features, making it an excellent choice for anyone looking to improve their indoor air quality. Its efficiency, ease of use, and effective odor reduction capabilities make it a worthwhile investment for healthier living spaces.