First Alert SA303, SA305, SA300 user manual HOW to Install this Smoke Alarm

Page 2

HOW TO INSTALL THIS SMOKE ALARM

THE PARTS OF THIS SMOKE ALARM

Alarm Base

1.Battery Compartment

2.Test button (Model SA300)

2.Test/Silence button (Models SA303 and SA305)

This unit is designed to be mounted on the ceiling, or on the wall if necessary.

1

3

2 2

3 4

5

The Parts of This Unit

1.Mounting Bracket

2.Mounting Slots and Screws

3.Locking Pins (break out of bracket)

4.Latch to Open Battery Compartment

5.Swing-Out Battery Compartment

To remove the mounting bracket from the Smoke Alarm base, hold the

DO NOT attach this Alarm to an electrical junction box. Attachment to an electrical box may impair the Alarm’s operation. Attach directly to wallboard or flat wall or ceiling surface.

Smoke Alarm base firmly and twist the mounting bracket counterclockwise.

FOLLOW THESE SIMPLE STEPS!

Tools you will need:

 

• Pencil

• Drill with 3/16” (5 mm) drill bit

• Hammer

• Standard Flathead screwdriver

1.Remove the mounting bracket from the Smoke Alarm base. Hold the mounting bracket against the ceiling (or wall) and make a mark at the center of each of the mounting slots with a pencil.

2.Put the unit where it won’t get covered with dust when you drill the mounting holes.

3.Using a 3/16” (5 mm) drill bit, drill a hole through each pencil mark.

4.Insert the plastic screw anchors (in the plastic bag with screws) into the holes. Tap the screw anchors gently with a hammer, if necessary, until they are flush with the ceiling or wall.

5.Tighten the screws (provided) into the screw anchors.

6. Activate the battery. With the battery

compartment open, install the battery

so the terminals on the battery match

+

the terminals on the Smoke Alarm.

 

Match “+” to “+” and “-” to “-.” Push

 

the battery in until it snaps in securely

 

and cannot be shaken loose.

 

If the battery is not snapped in completely, the unit cannot receive battery power. The Smoke Alarm may beep briefly when you install the battery—this is normal.

7.Position the base of the Smoke Alarm over the mounting bracket and turn. The Alarm can be positioned over the bracket every 60°. Turn the Smoke Alarm clockwise (right) until the unit is in place.

8.Test the Smoke Alarm. See “Weekly Testing.”

OPTIONAL LOCKING FEATURES

The locking features are designed to discourage unauthorized removal of the battery or Alarm. It is not necessary to activate the locks in single-family households where unauthorized battery or Alarm removal is not a concern.

These Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the

Locking Pin

Smoke Alarm to the mounting bracket. You can choose to use either feature independently, or use them both.

 

Tools you will need: Needle-nose pliers or utility knife • Standard Flathead screwdriver.

Both locking features use locking pins, which are molded into the mounting bracket. Using needle nose pliers or a utility knife, remove one or both pins from the mounting bracket, depending on how many locking features you want to use.

To permanently remove either lock, insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.

TO LOCK THE BATTERY COMPARTMENT

Do not lock the battery compartment until you have installed the battery and tested the unit.

1.Push and hold test button until the alarm sounds: 3 beeps, pause, 3 beeps, pause.

If the unit does not alarm during testing, DO NOT lock the battery compartment! Install a new battery and test again. If the Smoke Alarm still does not alarm, replace it immediately.

2. Using needle-nose pliers or a utility knife, detach one locking pin from the mounting bracket.

3. Push the locking pin through the hole near the battery drawer on the back of the Smoke Alarm.

TO UNLOCK THE BATTERY COMPARTMENT

1.Remove the Smoke Alarm from the mounting bracket. If the unit is locked to the bracket, see the section “To Unlock the Mounting Bracket.”

2.Insert a flathead screwdriver under the

head of the locking pin, and gently pry it out of the battery compartment lock. (If you plan to relock the battery compartment, save the locking pin.)

3.To relock the battery compartment, close the battery door and reinsert locking pin in lock.

4.Reattach the Smoke Alarm to the mounting bracket.

When replacing the battery, always test the Smoke Alarm before relocking the battery compartment.

TO LOCK THE MOUNTING BRACKET

1.Using needle-nose pliers, detach one locking pin from mounting bracket.

2.Insert the locking pin into the lock located on the pivoting hinge of the battery door.

3.When you attach the Smoke Alarm to the mounting bracket, the locking pin’s head will fit into a notch on the bracket.

TO UNLOCK THE MOUNTING BRACKET

1. Insert a flathead screwdriver between the mounting bracket pin and the mounting bracket.

2. Pry the Smoke Alarm away from the bracket by turning both the screwdriver

and the Smoke Alarm counterclockwise (left) at the same time.

2

Image 2
Contents Before YOU Install this Smoke Alarm Table of ContentsFire Safety Tips USER’S ManualHOW to Install this Smoke Alarm If this Smoke Alarm Sounds Weekly TestingRegular Maintenance If YOU Suspect a ProblemAgency Placement Recommendations Locations to Avoid for Smoke AlarmsInstalling Smoke Alarms in Mobile Homes & RVS Special Compliance Considerations About Smoke AlarmsLimitations of Smoke Alarms
Related manuals
Manual 6 pages 1.46 Kb

SA303, SA305, SA300 specifications

The First Alert SA300, SA305, and SA303 are advanced smoke and carbon monoxide detectors that provide crucial safety features to protect homes and families. These innovative devices combine modern technology with user-friendly designs to ensure optimal performance and reliability.

The First Alert SA300 is a dual-sensor smoke and fire alarm that employs both photoelectric and ionization sensing technologies. This dual-sensor capability allows the device to detect various types of smoke and fire quickly, including slow-smoldering fires as well as fast-flaming fires. The SA300 also features a battery backup system which ensures continuous operation during power outages. Its sleek design and easy installation process make it suitable for any home setting.

The SA305 model builds upon the features of the SA300 by integrating a carbon monoxide detector alongside its smoke detection capabilities. This all-in-one unit offers comprehensive protection against smoke and harmful carbon monoxide gas. The SA305 is equipped with a voice alarm feature that provides clear, verbal instructions during emergencies, ensuring occupants know how to respond appropriately. Additionally, it comes with a convenient LED indicator to show the status and functionality of the device.

Lastly, the First Alert SA303 is a smoke detector that focuses on photoelectric technology, making it particularly effective at detecting smoldering fires. The SA303 also includes features such as a tamper-resistant design and a low-battery chirp reminder, which alerts users to replace the battery before it runs out completely. With its compact size, the SA303 can be easily mounted on walls or ceilings, maximizing safety without compromising aesthetics.

In summary, the First Alert SA300, SA305, and SA303 are high-quality safety devices that cater to varied needs in fire and carbon monoxide detection. Their advanced technologies, such as dual-sensor capabilities, voice alarms, and reliable battery backup systems, make them essential components in any home safety plan. These devices not only enhance the security of households but also offer peace of mind to families, ensuring that they are protected against the dangers of fire and carbon monoxide. Investing in these detectors is a proactive step towards safeguarding loved ones and property.