Honeywell IPGSM-4GC manual Setup the Customer Account, Register the Communicator with AlarmNet

Page 4

IPGSM-4GC Commercial Fire Communicator – Installation and Setup Guide

STEP 1 – Setup the Customer Account

The communicator requires a subscriber account (customer account) to be setup with AlarmNet Direct. This is accomplished by registering the communicator with AlarmNet. Registering, enables the fire panel to send reports.

To setup the customer account you will need to contact the central monitoring station to get account information, and have access to the AlarmNet Direct website. To access the AlarmNet Direct website visit – https://services.alarmnet.com/AlarmNetDirect

If you do not wish to use the AlarmNet Direct website, you may call AlarmNet to setup the account, just phone 800- 222-6525, then select option 1. (Monday–Friday 8:00 am to 9:00 pm, Saturday 9:00 am to 5:30 pm EST)

Have the following information ready:

Primary City ID (two digits), obtained from your monitoring station.

Primary Central Station ID (two digits), obtained from your monitoring station.

Primary Subscriber ID (four digits), obtained from your monitoring station.

Communicator's MAC ID, and MAC CRC number located on outside of box, and inside the communicator.

Note: The SIM supplied for the IPGSM-4GC is already activated. Therefore no SIM activation is necessary.

STEP 2 – Register the Communicator with AlarmNet

Registering the communicator activates the account with AlarmNet and enables the fire system's control panel to send reports. There are three methods that can be used to register the communicator.

Register the communicator by logging into AlarmNet Direct and choosing “Show Programmed Devices GSM/I”. Search for the account using the Account Information or MAC ID. Under the “Actions” column, use the pulldown menu and choose Register. OR

After the IPGSM-4GC is installed and programmed, you can register the communicator by clicking the Tamper Switch 3 times. OR

After the IPGSM-4GC is installed and programmed, you can register the communicator using the 7720P Programming tool. Simply: Press [Shift ] then press []. Please wait for "Registration SUCCESS" message.

STEP 3 – Determine the Signal Strength and Select a Location

IMPORTANT - Do Not mount this device outdoors.

RF Exposure

Warning – The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.8 inches) from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.

When choosing a suitable mounting location, understand that signal strength is very important for proper operation. For most installations using the supplied antenna, mounting the unit as high as practical, and avoiding large metal components provides adequate signal strength for proper operation.

In this procedure, you will use the Communicator to determine signal strength in order to find a suitable mounting location.

Note: Since the SIM is already activated, the RSSI signal strength indicators will indicate signal strength.

1.For this procedure you will need a fully charged 12V battery.

2.Attach the Antenna Mounting Adapter, RF cable, and Antenna (see illustration on page 6).

2

Image 4
Contents IPGSM-4GC Contents General Information InstallationOperation Register the Communicator with AlarmNet Setup the Customer AccountDetermine the Signal Strength and Select a Location Mount and Wire PowerBoost1 Wiring for Grounds, Power, and RF Wiring the 659EN Line Fault Monitor Required for ULC Program the Communicator 7720P ProgrammerConfigure the Fire Panel Test the SystemDialer Capture Module Information LED Display InformationPowerBoost1 Information TroubleCommunicator Information GRNRF Specifications Central Station MessagesIPGSM-4GC Specifications IPGSM-4GC Trouble Detection InformationPage Page Page Page Page Page Page Wiring Diagram 1451-UL9 WiredÊ800-12458RŠ

IPGSM-4GC specifications

The Honeywell IPGSM-4GC is an advanced cellular communicator designed for security applications, providing reliable communication for alarm systems. This device enhances the ability of security systems to transmit signals to monitoring centers, ensuring that alarms are promptly addressed. With the increasing reliance on cellular technology, the IPGSM-4GC stands out as an essential tool for both residential and commercial security solutions.

One of the main features of the IPGSM-4GC is its dual-path communication capability. It can transmit signals via both Ethernet and cellular networks, providing redundancy that enhances reliability. In the event of an internet outage, the device seamlessly switches to cellular communication, ensuring that the alarm system remains operational at all times. This dual-path feature is particularly valuable in critical security applications where continuous communication is necessary.

The IPGSM-4GC also supports 4G LTE technology, which offers faster response times and improved signal quality compared to previous generation communicators. This technology enables the device to communicate with monitoring stations more efficiently, ensuring that alarm signals are sent and received quickly. Additionally, with 4G LTE being the current standard, the IPGSM-4GC is designed to remain relevant as older technologies are phased out.

Security is further enhanced by the robust encryption protocols employed by the IPGSM-4GC. The device uses advanced AES encryption, protecting sensitive data transmitted over cellular networks from potential interception or unauthorized access. This feature is crucial for users looking to maintain a high level of security in their alarm systems.

Installation and integration of the IPGSM-4GC are simplified thanks to its compatibility with a wide range of Honeywell alarm panels. The device utilizes a straightforward setup process, making it accessible for both professional installers and DIY enthusiasts. The modular design allows for easy updates and maintenance, ensuring longevity in performance.

In summary, the Honeywell IPGSM-4GC is a cutting-edge solution that combines dual-path communication, 4G LTE technology, and advanced encryption to provide a reliable and secure cellular communication option for alarm systems. With its ease of installation and compatibility with various Honeywell panels, it serves as a vital component for modern security solutions, meeting the demands of today’s connected world.