Honeywell XL 800 SERIES manual Types of Binary Input Modules, Signal Comment Minal

Page 26

Description of the I/O Modules

Excel 800

Binary Input Modules

Types of Binary Input Modules

Table 30. Excel 800 Binary Input Modules

type

description

housing

XF823

Panel Bus Binary Input Module

light-gray

 

 

 

XFL823

LONWORKS Bus Binary Input

dark-gray

 

Module

 

 

 

 

XS823

terminal socket

light-gray

 

 

 

Features

12 binary inputs

12 configurable status LEDs (green/red, yellow/OFF)

Binary inputs can be used as

– Static digital inputs as dry-contacts

Fig. 41. XF823AU Binary Input Module with terminal

socket

Legend

1Service button S1

2Hex switch S2

3Input LEDs

4Service LED

5Power LED

Functionality of service LED and power LED: see Table 42 and following.

Terminals

 

 

71

COM

COM

75

A

A

72

COM

COM

76

B

B

73

V~24

V~24

77

74 V~024

V~024

78

BI1

BI2

BI3

BI4

BI5

BI6

BI7

BI8

BI9

BI10

BI11

BI12

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

 

 

 

 

 

 

13

14

15

16

17

18

19

20

21

22

23

24

 

 

25

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 42. Terminal assignment and internal connections of

Binary Input Modules

Table 31. Description of Binary Input Module terminals

 

ter-

 

 

 

 

 

 

 

 

signal

 

comment

 

minal

 

 

 

 

2-wire communication bus (LON/Panel

71, 75

COM a

 

 

Bus)

 

 

 

 

72, 76

COM b

 

2-wire communication bus (LON/Panel

 

Bus)

 

 

 

 

73, 77

24 V~

 

Power supply

74, 78

24 V~0

 

Power supply

 

1 ─ 12

BI1 ─ BI12

Binary inputs 1 ─ 12

 

13 ─

GND

 

Ground. All grounds are connected

24

 

internally to each other.

 

 

25, 26

 

 

Shield connection (functional earth),

 

 

internally connected to the DIN rail.

 

 

 

 

NOTE: Shield connection to be used for shielded I/O cables only. It is not allowed to connect a LONWORKS shield.

Technical Data

Table 32. Technical data for of Binary Input Modules

input type

dry-contact

current rating (closed

2 mA

input)

 

open contact voltage

16 ─ 22 VDC

 

 

EN1B-0410GE51 R0908A

26

Image 26
Contents XL 800 Series Trademark Information TroubleshootingGeneral General Before InstallationInstallation Wiring XL800 Series Power Consumption Modules BUS Modules Description of the XCL8010AU Controller Module OverviewTypical 14507287-001 Power Module wiring Description of the XCL8010AU Controller Module ExcelController Transformer GRN Interfaces and Bus Connections Technical DataSmoke Control Configuration System DataConnecting Single Bus Controller Systems Panel ResetTypical Power Limited Circuit for XL800 Data File Set-UpXCL8010AU, I/O Modules on Single Rail Connecting I/O ModulesConnecting I/O Modules to the XCL8010AU Multiple Rails in Single CabinetSetting Address of Panel Bus I/O Modules HEX switch settings and addresses AddressLonworks Bus Topologies Setting the I/O Bus SwitchMounting/Dismounting Modules Bus TopologiesMounting Sockets Connecting SocketsMounting/Dismounting Controller/Sockets Risk of malfunctionDismounting Sockets Disconnecting SocketsMounting/Dismounting Electronic Modules Mounting Electronic ModulesConnecting via C-Bus Connecting HMIs or LaptopsLonworks Service LED and Button FeaturesConnecting Laptops XL-Online/CARE XCL8010AU TerminalsHMI Interface Reset ButtonBus Tx LED and Rx LED Watchdog Status Alarm and Power LEDsBus Switch S2 Modem InterfaceDescription of the I/O Modules Common FeaturesBus Termination Switch S1 MemoryTerminals Types of Analog Input Modules FeaturesAnalog Input Modules XFL821AU Connection Examples XFL821AU Analog Input ModuleTypes of Analog Output Modules Technical DataAnalog Output Modules TerminalsDamage to the electronic module Modules with Manual OverridesXFL822AU Connection Example Binary Input Modules Excel 800 Binary Input Modules Type Description HousingSignal Comment Minal Types of Binary Input ModulesStatus LEDs XF823AU Connection ExamplesTypes of Relay Output Modules Excel 800 Relay Output Modules Type Description HousingRelay Output Modules Permissible Loads Status LEDs with Manual OverridesXF824AU connection example XFR825AU connection exampleTroubleshooting on the XCL8010AU Controller TroubleshootingTesting Wiring Connections Power LED greenXCL8010AU alarm LED Case Alarm LED Meaning Remedy Alarm LED redLonworks Service LED Bus Tx and Rx LEDs HMI Tx and Rx LEDsModules Troubleshooting Power LED of I/O ModulesService LED of I/O modules Case Meaning Remedy Service LED of I/O ModulesExcel 800Troubleshooting Automation and Control Solutions

XL 800 SERIES specifications

The Honeywell XL 800 Series represents a significant advancement in the realm of flight management systems, tailored for general aviation aircraft. This series stands out due to its combination of state-of-the-art technology, user-friendly interface, and comprehensive functionality, all designed to enhance safety and operational efficiency for pilots.

One of the main features of the XL 800 Series is its advanced flight planning capabilities. The system is equipped with a robust database that allows pilots to create, modify, and execute flight plans with unprecedented ease. The built-in terrain awareness tools provide real-time information about geographical obstacles, helping mitigate the risk of Controlled Flight Into Terrain (CFIT). The intuitive graphical user interface offers a clear view of the flight path, airspace constraints, and available alternatives, enabling pilots to make informed decisions.

The XL 800 Series also boasts cutting-edge navigation technologies, including GPS, RNAV, and WAAS (Wide Area Augmentation System) support. These technologies ensure that flights are accurately tracked and that pilots remain on course, enhancing navigation reliability. Additionally, the system includes advanced autopilot features, which allow for smoother transitions during flight phases and can significantly reduce pilot workload.

Another notable characteristic of the XL 800 Series is its connectivity. The system supports data link services that enable real-time weather updates and air traffic control communication. This connectivity not only improves situational awareness, but it also equips pilots with the necessary tools to adapt to changing flight conditions promptly.

Furthermore, the Honeywell XL 800 Series prioritizes safety with integrated safety features, including enhanced cockpit alerting systems. These systems proactively notify pilots of potential hazards, such as deviations from the flight path or adverse weather conditions, ensuring that safety remains paramount throughout the flight.

In summary, the Honeywell XL 800 Series encapsulates a wide array of features and technologies that serve to elevate the flying experience for general aviation pilots. Through its emphasis on flight planning, navigation, connectivity, and safety, it stands as a reliable and sophisticated solution that meets the demands of modern aviation. Whether enhancing safety, improving navigation accuracy, or simplifying flight planning, the XL 800 Series is a premier choice for those seeking an advanced flight management system.