BRK electronic M06-2016-007, 4120B user manual Inside this Manual, Other Features of Smoke Alarms

Page 2

INSIDE THIS MANUAL

Where To Install Smoke Alarms . . . . . . . . .1 Where Not To Install Smoke Alarms . . . . . .3 Important! Read Before You Install

This Smoke Alarm . . . . . . . . . . . . . . . . . . .5

Understanding the Indicator Lights

and Alarm Horn Patterns. . . . . . . . . . . . . . . . 6

Optional Locking Features . . . . . . . . . . . . .7 How To Install This Smoke Alarm . . . . . . .10

Installing a Single (Stand Alone)

Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . 11

Interconnecting Multiple Smoke Alarms . . . 12

Testing and Maintenance . . . . . . . . . . . . .14

If This Smoke Alarm Sounds. . . . . . . . . . .15

Using The Silence Feature

(Cat. 4120SB Only) . . . . . . . . . . . . . . . . . .16

Protecting Your Family From Fire . . . . . . .17

What To Do In Case Of Fire. . . . . . . . . . . .18

If Your Smoke Alarm Needs Service . . . . .18

Troubleshooting . . . . . . . . . . . . . . . . . . . .19

Special Compliance Considerations . . . . .20

Limitations Of Smoke Alarms . . . . . . . . . .21

10-Year Limited Warranty . . . . BACK COVER

IMPORTANT!

PLEASE READ CAREFULLY AND SAVE.

This user’s manual contains important information about your smoke alarm’s operation. If you are installing this smoke alarm for use by others, you must leave this manual--or a copy of it--with the end user.

Other Features of Smoke Alarms

Battery (DC) operated smoke alarms: Provide protection even when electricity fails, provided the batteries are fresh and correctly installed. Units are easy to install, and do not require professional installation.

AC powered smoke alarms: Can be interconnected so if one unit senses smoke, all units alarm. They do not operate if electricity fails. Units must be installed by a qualified electrician.

AC/DC powered smoke alarms: (AC with battery back-

up): Can be interconnected so if one unit senses smoke, all units alarm. They will operate if electricity fails, provided the batteries are fresh and correctly installed. Units must be installed by a qualified electrician.

Smoke alarms for the hearing impaired: Special purpose smoke alarms should be installed for the hearing impaired. They include a visual alarm and an audible alarm horn, and meet the requirements of the Americans With Disabilities Act. These units can be interconnected so if one unit senses smoke, all units alarm. They do not operate if electricity fails. Units must be installed by a qualified electrician. BRK Electronics® Cat. 100S is an AC powered unit that has an 85 decibel alarm and a 177 candela strobe light, which flashes rapidly when the unit is in alarm.

All these units are designed to provide early warning of fires if located, installed and cared for as described in the user’s manual, and if smoke reaches them. If you are unsure which type of unit to install, refer to Chapter 2 of the National Fire Protection Association (NFPA) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code). National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building codes may also require specific units in new construction or in different areas of the home.

Image 2
Contents User’s Manual Other Features of Smoke Alarms Inside this ManualWhere To Install Smoke Alarms NEW ConstructionNfpa Standard 72 Section Agency Placement RecommendationsMore specifically, install smoke alarms California State Fire Marshall Where Not To Install Smoke AlarmsFor best performance, do not install the unit Avoiding Dead Air Spaces Important! Read Before You Install This Smoke Alarm Understanding The Indicator Lights and Alarm Horn Patterns Important Installation Parts Optional Locking FeaturesTo Lock The Battery Compartment To Lock The Mounting Bracket How To Install This Smoke Alarm Parts Of This UnitInstalling a Single Stand-Alone Smoke Alarm Tools you will need Standard/Flathead screwdriverInterconnecting Multiple Smoke Alarms Interconnecting Multiple Smoke Alarms To install and interconnect multiple alarmsRegular Maintenance Testing and MaintenanceWeekly Testing Choosing a replacement batteryIf This Smoke Alarm Sounds Responding To An AlarmCat SB Only Using The Silence Feature To silence smoke alarms An interconnected seriesProtecting Your Family From Fire If Your Smoke Alarm Needs Service What To Do Case Of FireTroubleshooting Hotels/Motels Special Compliance ConsiderationsSingle-Family Residence Limitations Of Smoke Alarms Year Limited Warranty

4120B, M06-2016-007 specifications

The BRK electronic M06-2016-007,4120B is a cutting-edge detection device designed for modern safety needs. This model exemplifies BRK's commitment to innovation, reliability, and user-friendly functionality. The M06-2016-007,4120B is primarily a smoke and carbon monoxide detector, ensuring comprehensive protection against two of the most prevalent household hazards.

One of the standout features of this model is its advanced photoelectric sensing technology. Unlike traditional ionization smoke detectors that rely on radioactive materials, the photoelectric sensor uses light beams to detect smoke particles effectively. This technology is particularly adept at identifying smoldering fires, which can produce higher amounts of smoke before bursting into flames, ultimately leading to quicker alerts for homeowners.

In addition to its smoke detection capabilities, the M06-2016-007,4120B efficiently monitors carbon monoxide levels. Carbon monoxide is a colorless, odorless gas that can be deadly in high concentrations. The detector continuously samples the air and provides real-time readings to alert occupants when levels become dangerous. This dual functionality makes the M06-2016-007,4120B a two-in-one safety device, underscoring its versatility.

The alarm system of the M06-2016-007,4120B is robust and designed for maximum audibility, ensuring that even in the sleep state, alerts can be heard. It features a loud siren that meets industry standards, providing reassurance that occupants will be warned in the event of an emergency.

Powering the device is a reliable battery backup that ensures continued operation even in power outages, making it a dependable choice for safety-conscious consumers. Furthermore, the device incorporates a low-battery alert feature to remind users when it's time to replace the batteries, enhancing ongoing reliability.

Moreover, the M06-2016-007,4120B boasts an easy installation process, allowing homeowners to set it up without the need for professional assistance. The compact design ensures it can fit seamlessly into various home environments without being intrusive.

In conclusion, the BRK electronic M06-2016-007,4120B is a highly effective smoke and carbon monoxide detector that combines advanced technology with practical safety features. Its photoelectric sensing, dual detection capabilities, and reliable power backup position it as a must-have for any household looking to enhance its safety measures.