BRK electronic CO5120PDB user manual Activating the Battery BACK-UP, Wall Mounting

Page 15

ELECTRICAL SHOCK HAZARD. Do not restore power until the CO Alarm is completely installed. Restoring power before installation is complete may result in serious electrical shock, injury or death.

7.Make sure the unit is receiving AC power. Under normal operation, the red indicator light will shine continuously. Display shows a dash under “READY”.

8.If the red power indicator light does not light,

TURN OFF POWER TO THE JUNCTION BOX and recheck all connections. If all connections are correct and the red power indicator still does not light when you restore the power, the unit should be replaced immediately.

WALL MOUNTING:

 

1.

Position the junction box face

 

 

plate so screw holes are posi-

 

 

tioned as shown at right.

 

2.

Remove mounting bracket

 

 

from the base. Position the

 

 

screw slots on the mounting

Enlarged view

 

bracket over the screws in the

 

 

 

junction box. Tighten the

 

 

screws.

 

3.

Using wire nuts, connect the

 

 

power connector to the AC

 

 

power.

 

Connect the white wire on the power connector to the neutral wire in the junction box.

Connect the black wire on the power connector to the hot wire in the junction box.

Tuck the violet wire inside the junction box. It is used for interconnect only.

4.Plug the power connector into back of the unit.

5. Position the base of the Alarm over the mounting bracket so display is rotated approximately 30º left of center. Turn the unit clockwise (right) until display is horizontal and the unit is in place.

6.Make sure CO Alarm is secured to mounting bracket.

7.If you are only installing one unit, restore power to the junction box.

ELECTRICAL SHOCK HAZARD. Do not restore power until the CO Alarm is completely installed. Restoring power before installation is complete may result in serious electrical shock, injury or death.

8.Make sure the unit is receiving AC power. Under normal operation, the red indicator light will shine continuously. Display shows a dash under “READY”.

9.If the red power indicator light does not light,

TURN OFF POWER TO THE JUNCTION BOX and recheck all connections. If all connections are correct and the red power indicator still does not light when you restore the power, the unit should be replaced immediately.

ACTIVATING THE BATTERY BACK-UP

Activate the battery back-up by removing the “Pull to Activate Battery Back-Up” tab. You do not need to open the battery compartment and reposition the bat- tery during installation. DO NOT remove the battery activation tab until AC power is turned on to con- serve battery power. Test the alarm. Press and hold the test button on the cover until the alarm sounds: 4 beeps, pause, 4 beeps, pause.

13

Image 15
Contents Please Read Carefully and Save FeaturesModel CO5120PDB-USER’S Manual 120VAC 60 Hz 0.09AIntroduction Table of ContentsBasic safety information HOW Your CO Alarm Works Cover of Your CO AlarmWhat YOU see and Hear Under Different Conditions Understanding Your CO AlarmBasic Power Conditions PowerWhat You See and Hear Under Different Conditions If battery becomes low or is missing HornIf the CO alarm is not operating properly Horn Alarm levels of CO are detected Over 70 ppmTo check CO Memory Using the CO MemoryIf you silence the alarm Horn What You See and Hear If CO Is DetectedCO Alarm Specifications Where to Install CO Alarms A SINGLE-LEVEL HomeA MULTI-LEVEL Home Do not locate this CO Alarm Where not to Install this AlarmTools you will need Needle-nose pliers Using the Optional Locking FeaturesBattery Compartment Lock To Lock the Battery CompartmentTo Unlock the Battery Compartment To Lock the Battery CompartmentTo Deactivate the Bracket Lock Mounting Bracket LockTools you will need To Activate the Bracket LockTo Deactivate the Bracket Lock HOW to Install Your CO AlarmBefore YOU Begin Installation To Permanently Remove Bracket LockParts of this CO Alarm SINGLE-STATION InstallationCeiling Mounting Wall Mounting Activating the Battery BACK-UPInterconnecting Multiple CO Alarms Interconnecting Multiple CO AlarmsMULTIPLE-STATION Installation Wall Mounting Do not remove or disconnect the alarm If the Alarm SoundsIt Means Using the Silence FeatureWhile the CO Alarm is silenced If the CO Alarm...remains silentFinding the Source of CO After AN Alarm Latching Alarm Indicator KEYInterconnected Alarms LOW or Missing Battery Warning Testing and MaintenanceWeekly Testing Regular MaintenanceWhat is CO? Symptoms of CO PoisoningWhat YOU Need to Know about CO Following conditions can result in transient CO situations Potential Sources of CO in the HomeHOW can I Protect MY FAMILY? What Levels of CO Cause AN ALARM? UL2034 Required Alarm PointsUnderwriters Laboratories INC. UL2034 If your CO Alarm does this This means You should Troubleshooting GuideGeneral Limitations of CO Alarms Page How to Obtain Warranty Service Limited Warranty

CO5120PDB specifications

The BRK electronic CO5120PDB is a state-of-the-art combination carbon monoxide and smoke detector that offers enhanced safety features for modern homes. Designed with innovation in mind, this device aims to provide reliable protection against the dangers of carbon monoxide poisoning and smoke inhalation from fires.

One of the standout features of the CO5120PDB is its dual-sensor technology. It incorporates both photoelectric and ionization sensors. The photoelectric sensor is highly effective in detecting slow-burning fires that produce a lot of smoke, while the ionization sensor is adept at detecting fast-flaming fires. This combination ensures comprehensive smoke detection, providing a higher level of safety and peace of mind for homeowners.

In addition to its advanced smoke detection capabilities, the CO5120PDB is equipped with a highly sensitive carbon monoxide sensor. Carbon monoxide is an insidious gas that cannot be seen or smelled, making it a silent threat in many households. The CO sensor can quickly identify dangerous levels of this gas, sounding an alarm to alert residents and help them take necessary action.

The CO5120PDB features a user-friendly design, including a digital display that shows the current CO levels in parts per million (ppm). This allows users to monitor the levels of carbon monoxide in real time. The detector also comes with a voice alert feature, providing clear and understandable warnings in the event of smoke or CO detection, which helps in identifying the situation promptly.

Another significant characteristic of the CO5120PDB is its ability to operate even during power outages. It is equipped with a battery backup system that ensures continuous operation, making it ideal for locations where power interruptions may occur. Additionally, the device has a test/silence button that allows users to test the unit for functionality as well as silence false alarms if necessary.

Installation is straightforward with the CO5120PDB, which can be mounted on walls or ceilings, adhering to the recommendations of safety organizations regarding placement. The unit also features a sleek design that blends seamlessly into home decor, ensuring that safety doesn’t compromise aesthetics.

In conclusion, the BRK electronic CO5120PDB is an exemplary choice for those seeking robust protection against both carbon monoxide and smoke. Its dual-sensor technology, digital display, voice alerts, and battery backup make it an indispensable addition to any household, ensuring that residents can live with comfort and peace of mind, knowing they are protected from two of the most significant indoor hazards.