BRK electronic CO5120PDB user manual Table of Contents, Introduction

Page 2

TABLE OF CONTENTS

Chapter 1: Introduction . . . . . . . . . . .Inside Cover

Basic Safety Information . . . . . . . . .Inside Cover

How Your CO Alarm Works . . . . . . . . . . . . . . . .1

Understanding Your CO Alarm . . . . . . . . . . . . .2

Using the CO Memory . . . . . . . . . . . . . . . . . . .4

CO Alarm Specifications . . . . . . . . . . . . . . . . . .5

Chapter 2: Installation . . . . . . . . . . . . . . . . . . . . . .6

Where to Install CO Alarms . . . . . . . . . . . . . . . .6 Where NOT To Install CO Alarms . . . . . . . . . . . .7 Using the Locking Features . . . . . . . . . . . . . . . .8 How to Install Your CO Alarm . . . . . . . . . . . . .11

Chapter 3: If Your CO Alarm Sounds . . . . . . . . .17

If the Alarm Sounds . . . . . . . . . . . . . . . . . . . . .17 Using the Silence Feature . . . . . . . . . . . . . . . .18 Finding the Source of CO After an Alarm . . . . .19 The Latching Alarm Indicator . . . . . . . . . . . . . .19

Chapter 4: Testing and Maintenance . . . . . . . . .20

Chapter 5: What You Need To Know About CO .21

What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . .21 Symptoms of CO Poisoning . . . . . . . . . . . . . .21 Finding the Source of CO After an Alarm . . . . .21

Potential Sources Of CO In The Home . . . . . .22 How Can I Protect My Family? . . . . . . . . . . . .23

Chapter 6: Underwriters Laboratories, Inc. UL2034 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

Chapter 7: Troubleshooting Guide . . . . . . . . . . .25

Chapter 8: General Limitations

Of CO/Smoke Alarms . . . . . . . . . . . . . . . . . . . . .26

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . .27

CHAPTER 1: INTRODUCTION

BASIC SAFETY INFORMATION

Dangers, Warnings, and Cautions alert you to impor- tant operating instructions or to potentially hazardous situations. Pay special attention to these items.

THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect carbon monoxide from ANY source of combustion. It is NOT designed to detect smoke, fire, or any other gas.

This CO Alarm is approved for use in single-family residences. It is NOT designed for marine or RV use.

This CO Alarm will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas.

The Silence Feature is for your convenience only and will not correct a CO problem. Always check your home for a potential problem after any alarm. Failure to do so can result in injury or death.

This unit does not work without power. If the AC power fails, the battery back-up will power the alarm for at least 20 hours provided the 9V battery is fresh and correctly installed.

Image 2
Contents 120VAC 60 Hz 0.09A FeaturesModel CO5120PDB-USER’S Manual Please Read Carefully and SaveTable of Contents IntroductionHOW Your CO Alarm Works Cover of Your CO Alarm Basic safety informationPower Understanding Your CO AlarmBasic Power Conditions What YOU see and Hear Under Different ConditionsAlarm levels of CO are detected Over 70 ppm If battery becomes low or is missing HornIf the CO alarm is not operating properly Horn What You See and Hear Under Different ConditionsWhat You See and Hear If CO Is Detected Using the CO MemoryIf you silence the alarm Horn To check CO MemoryCO Alarm Specifications A MULTI-LEVEL Home Where to Install CO AlarmsA SINGLE-LEVEL Home Where not to Install this Alarm Do not locate this CO AlarmTo Lock the Battery Compartment Using the Optional Locking FeaturesBattery Compartment Lock Tools you will need Needle-nose pliersTo Lock the Battery Compartment To Unlock the Battery CompartmentTo Activate the Bracket Lock Mounting Bracket LockTools you will need To Deactivate the Bracket LockTo Permanently Remove Bracket Lock HOW to Install Your CO AlarmBefore YOU Begin Installation To Deactivate the Bracket LockCeiling Mounting Parts of this CO AlarmSINGLE-STATION Installation Activating the Battery BACK-UP Wall MountingInterconnecting Multiple CO Alarms Interconnecting Multiple CO AlarmsMULTIPLE-STATION Installation Wall Mounting If the Alarm Sounds Do not remove or disconnect the alarmIf the CO Alarm...remains silent Using the Silence FeatureWhile the CO Alarm is silenced It MeansInterconnected Alarms Finding the Source of CO After AN AlarmLatching Alarm Indicator KEY Regular Maintenance Testing and MaintenanceWeekly Testing LOW or Missing Battery WarningWhat YOU Need to Know about CO What is CO?Symptoms of CO Poisoning Potential Sources of CO in the Home Following conditions can result in transient CO situationsHOW can I Protect MY FAMILY? Underwriters Laboratories INC. UL2034 What Levels of CO Cause AN ALARM?UL2034 Required Alarm Points Troubleshooting Guide If your CO Alarm does this This means You shouldGeneral Limitations of CO Alarms Page Limited Warranty How to Obtain Warranty Service

CO5120PDB specifications

The BRK electronic CO5120PDB is a state-of-the-art combination carbon monoxide and smoke detector that offers enhanced safety features for modern homes. Designed with innovation in mind, this device aims to provide reliable protection against the dangers of carbon monoxide poisoning and smoke inhalation from fires.

One of the standout features of the CO5120PDB is its dual-sensor technology. It incorporates both photoelectric and ionization sensors. The photoelectric sensor is highly effective in detecting slow-burning fires that produce a lot of smoke, while the ionization sensor is adept at detecting fast-flaming fires. This combination ensures comprehensive smoke detection, providing a higher level of safety and peace of mind for homeowners.

In addition to its advanced smoke detection capabilities, the CO5120PDB is equipped with a highly sensitive carbon monoxide sensor. Carbon monoxide is an insidious gas that cannot be seen or smelled, making it a silent threat in many households. The CO sensor can quickly identify dangerous levels of this gas, sounding an alarm to alert residents and help them take necessary action.

The CO5120PDB features a user-friendly design, including a digital display that shows the current CO levels in parts per million (ppm). This allows users to monitor the levels of carbon monoxide in real time. The detector also comes with a voice alert feature, providing clear and understandable warnings in the event of smoke or CO detection, which helps in identifying the situation promptly.

Another significant characteristic of the CO5120PDB is its ability to operate even during power outages. It is equipped with a battery backup system that ensures continuous operation, making it ideal for locations where power interruptions may occur. Additionally, the device has a test/silence button that allows users to test the unit for functionality as well as silence false alarms if necessary.

Installation is straightforward with the CO5120PDB, which can be mounted on walls or ceilings, adhering to the recommendations of safety organizations regarding placement. The unit also features a sleek design that blends seamlessly into home decor, ensuring that safety doesn’t compromise aesthetics.

In conclusion, the BRK electronic CO5120PDB is an exemplary choice for those seeking robust protection against both carbon monoxide and smoke. Its dual-sensor technology, digital display, voice alerts, and battery backup make it an indispensable addition to any household, ensuring that residents can live with comfort and peace of mind, knowing they are protected from two of the most significant indoor hazards.