BRK electronic CO5120PDB Parts of this CO Alarm, SINGLE-STATION Installation, Ceiling Mounting

Page 14

THE PARTS OF THIS CO ALARM

1

3

2

2

6

3

4

5

 

7

8

9

1Mounting Bracket

2Mounting Slot and Screw

3Locking Pins (break out of bracket)

4Hot (Black) AC Wire

5Neutral (White) AC Wire

6Interconnect Wire (Violet)

7Lever to Open Battery Compartment

8Swing-Out Battery Compartment

9Quick-Connect Power

SINGLE-STATION INSTALLATION

Tools needed: Standard/Flathead screwdriver.

ELECTRICAL SHOCK HAZARD. Turn off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation. Failure to turn off the power before installation may result in serious electrical shock, injury or death.

CEILING MOUNTING:

1. Remove the mounting bracket from the base. Position the screw slots on the mounting bracket over the screws in the junction box. Tighten the screws.

2. Using wire nuts, connect the power connector to the AC power.

Connect the white wire on the power

connector to the neutral wire in the junction box.

Connect the black wire on the

power connector to the hot wire in the junction box.

• Tuck the violet wire inside the junction box. It is used for interconnect only.

3.Plug the power connector into back of the unit.

4.Position the base of the Alarm over the mounting bracket and turn. The Alarm can be

positioned over the bracket every 60°. Turn the unit clockwise (right) until the unit is in place.

5. Make sure CO Alarm is secured to mounting bracket.

6.If you are only installing one unit, restore power to the junction box.

12

Image 14
Contents 120VAC 60 Hz 0.09A FeaturesModel CO5120PDB-USER’S Manual Please Read Carefully and SaveTable of Contents IntroductionHOW Your CO Alarm Works Cover of Your CO Alarm Basic safety informationPower Understanding Your CO AlarmBasic Power Conditions What YOU see and Hear Under Different ConditionsAlarm levels of CO are detected Over 70 ppm If battery becomes low or is missing HornIf the CO alarm is not operating properly Horn What You See and Hear Under Different ConditionsWhat You See and Hear If CO Is Detected Using the CO MemoryIf you silence the alarm Horn To check CO MemoryCO Alarm Specifications A MULTI-LEVEL Home Where to Install CO AlarmsA SINGLE-LEVEL Home Where not to Install this Alarm Do not locate this CO AlarmTo Lock the Battery Compartment Using the Optional Locking FeaturesBattery Compartment Lock Tools you will need Needle-nose pliersTo Lock the Battery Compartment To Unlock the Battery CompartmentTo Activate the Bracket Lock Mounting Bracket LockTools you will need To Deactivate the Bracket LockTo Permanently Remove Bracket Lock HOW to Install Your CO AlarmBefore YOU Begin Installation To Deactivate the Bracket LockCeiling Mounting Parts of this CO AlarmSINGLE-STATION Installation Activating the Battery BACK-UP Wall MountingInterconnecting Multiple CO Alarms Interconnecting Multiple CO AlarmsMULTIPLE-STATION Installation Wall Mounting If the Alarm Sounds Do not remove or disconnect the alarmIf the CO Alarm...remains silent Using the Silence FeatureWhile the CO Alarm is silenced It MeansInterconnected Alarms Finding the Source of CO After AN AlarmLatching Alarm Indicator KEY Regular Maintenance Testing and MaintenanceWeekly Testing LOW or Missing Battery WarningWhat YOU Need to Know about CO What is CO?Symptoms of CO Poisoning Potential Sources of CO in the Home Following conditions can result in transient CO situationsHOW can I Protect MY FAMILY? Underwriters Laboratories INC. UL2034 What Levels of CO Cause AN ALARM?UL2034 Required Alarm Points Troubleshooting Guide If your CO Alarm does this This means You shouldGeneral Limitations of CO Alarms Page Limited Warranty How to Obtain Warranty Service

CO5120PDB specifications

The BRK electronic CO5120PDB is a state-of-the-art combination carbon monoxide and smoke detector that offers enhanced safety features for modern homes. Designed with innovation in mind, this device aims to provide reliable protection against the dangers of carbon monoxide poisoning and smoke inhalation from fires.

One of the standout features of the CO5120PDB is its dual-sensor technology. It incorporates both photoelectric and ionization sensors. The photoelectric sensor is highly effective in detecting slow-burning fires that produce a lot of smoke, while the ionization sensor is adept at detecting fast-flaming fires. This combination ensures comprehensive smoke detection, providing a higher level of safety and peace of mind for homeowners.

In addition to its advanced smoke detection capabilities, the CO5120PDB is equipped with a highly sensitive carbon monoxide sensor. Carbon monoxide is an insidious gas that cannot be seen or smelled, making it a silent threat in many households. The CO sensor can quickly identify dangerous levels of this gas, sounding an alarm to alert residents and help them take necessary action.

The CO5120PDB features a user-friendly design, including a digital display that shows the current CO levels in parts per million (ppm). This allows users to monitor the levels of carbon monoxide in real time. The detector also comes with a voice alert feature, providing clear and understandable warnings in the event of smoke or CO detection, which helps in identifying the situation promptly.

Another significant characteristic of the CO5120PDB is its ability to operate even during power outages. It is equipped with a battery backup system that ensures continuous operation, making it ideal for locations where power interruptions may occur. Additionally, the device has a test/silence button that allows users to test the unit for functionality as well as silence false alarms if necessary.

Installation is straightforward with the CO5120PDB, which can be mounted on walls or ceilings, adhering to the recommendations of safety organizations regarding placement. The unit also features a sleek design that blends seamlessly into home decor, ensuring that safety doesn’t compromise aesthetics.

In conclusion, the BRK electronic CO5120PDB is an exemplary choice for those seeking robust protection against both carbon monoxide and smoke. Its dual-sensor technology, digital display, voice alerts, and battery backup make it an indispensable addition to any household, ensuring that residents can live with comfort and peace of mind, knowing they are protected from two of the most significant indoor hazards.