Hearth and Home Technologies SL-950TR-D, SL-750TR-D Vent Information and Diagrams, Vent Table Key

Page 12

5 Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

 

 

V1

First section (closest to appliance) of vertical length

 

 

V2

Second section of vertical length

 

 

H1

First section (closest to appliance) of horizontal length

 

 

H2

Second section of horizontal length

 

 

WARNING

Fire Hazard. Explosion Risk. Asphyxiation Risk.

Do NOT connect this gas appliance to a chimney flue serving a separate solid-fuel or gas burning appliance.

• Vent this appliance directly outside.

• Use separate vent system for this appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

B. Use of Elbows

CAUTION

ALL vent configuration specifications MUST be followed.

This product is tested and listed to these specifications.

Appliance performance will suffer if specifications are not followed.

Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect (see Figure 5.1).

Two 450 elbows may be used in place of one 900 elbow. On 450 runs, one foot of diagonal is equal to 8.5 inches horizontal run and 8.5 inches vertical run. A length of straight pipe is allowed between two 450 elbows (see Figure 5.1).

Vertical in.1/2 -8

8-1/2 in.

Horizontal

Figure 5.1

C. Measuring Standards

Vertical and horizontal measurements listed in the vent diagrams were made using the following standards.

1.Pipe measurements are shown using the effective length of pipe (see Figure 5.2).

2.Measurements are made from the appliance outer wrap, not from the standoffs.

3.Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 4.1).

4.Vertical terminations are measured to bottom of termina- tion cap.

5.Horizontal pipe installed level with no rise.

 

Pipe

Effective Length

 

Inches

Millimeters

 

 

 

DVP4

4

102

 

DVP6

6

152

Effective

DVP12

12

305

Height/Length

DVP24

24

610

 

 

DVP36

36

914

 

DVP48

48

1219

 

DVP6A

3 to 6

76 to 152

 

DVP12A

3 to 12

76 to 305

 

DVP12MI

3 to 12

76 to 305

 

DVP24MI

3 to 24

76 to 610

Figure 5.2 DVP Pipe Effective Length

 

 

12

Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/06

Image 12
Contents Models SL-550TR-D SL-750TR-D SL-950TR-D What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Design and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededFraming and Clearances Selecting Appliance LocationModels Constructing the Appliance Chase ClearancesMantel Projections Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Minimum Clearances for TerminationVent Information and Diagrams Vent Table KeyUse of Elbows Measuring StandardsUse of Flex Vent Vent Diagrams Top Vent Horizontal Termination Venting with 1 elbow NGTop Vent Horizontal Termination Venting with 2 elbows NG MinimumTop Vent Horizontal Termination Venting with 3 elbows NG Baffle Instruction Components onlyTop Vent Vertical Termination Venting with 2 elbows NG Top Vent Vertical Termination Venting with 2 elbows PropaneTop Vent Vertical Termination Venting with 3 elbows NG Top Vent Vertical Termination Venting with 3 elbows PropaneH1 = 9 in mm Maximum Rear Vent Horizontal Termination Venting with 2 elbows Rear Vent Horizontal Termination Venting with 3 elbowsRear Vent Vertical Termination Venting with 1 elbow Rear Vent Vertical Termination Venting with 2 elbowsRear Vent Vertical Termination Venting with 3 elbows V1 MIN H1 MAX H2 MAXVent Clearances and Framing Pipe Clearances to Combustibles Wall Penetration FramingCombustible Wall Penetration Non-Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Choosing the Top or Rear VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance Fire Risk Prevent contact with sagging, loose insulationInstalling Vent Pipe Assembly of Vent Sections DVP Pipe onlyAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsDisassembly of Vent Sections DVP Pipe onlySecuring the Vent Sections Vertical Sections Horizontal SectionsAssembly of Vent Sections SL Series Pipe only Install Support BracketsAttach the First Vent Component to Starting Collars Continue Adding Vent ComponentsInstalling the Horizontal Termination Cap Heat Shield Requirements for Horizontal TerminationFire Risk. Explosion Risk Installing Roof Flashing and Vertical Termination Cap 16 Minimum Height from Roof to Lowest Discharge OpeningAssembling and Installing Storm Collar 19 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Connecting to the ApplianceElectrical Information Standing Pilot Ignition System Wiring Intellifire Ignition System WiringJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialSee for combustible/non-combustible definitions Appliance Setup Clean the ApplianceAccessories Remove Shipping MaterialsLog Set Assembly LOGS-SL550-D Models SL-550TR-D Positioning the LogsTAB Locator Log Set Assembly LOGS-SL750-D Models SL-750TR-D, SL-950TR-D Notches Raised Flat Spots Glass Assembly Removing Glass AssemblyReplacing Glass Assembly Shutter SettingsOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance Turn on all electric power to the applianceLighting Appliance This appliance is equipped with an ignitionFor Your Safety Read Before Lighting Instructions Standing Pilot IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Sympton Possible Cause Corrective ActionSure must not exceed 14 in. W.C Maintaining and Servicing Appliance Inspect Maintenance Tasks Recommend addition of screen if one is not presentAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45 45 ElbowDVP-TRAP 13-1/4 367 mm13-7/8 352 mm 241 mm 356 mm98 mm 10-1/2Vertical Termination Cap 184 mm 12-1/2 318 mm 133 mm Vertical Termination Cap High windSL Series Vent Components Pipe Length/InchesService Parts Log Set AssemblyService Parts List Additional service part numbers may appear on the followingSL-750TR-D 215Additional service part numbers may appear on the following SL-750TR-DSL-950TR-D 216Service Parts List SL-550 / 750 / 950TR-D-IPI Intermittent Pilot IgnitionSL-550 / 750 / 950TR-D Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information

SL-950TR-D, SL-750TR-D, SL-550TR-D specifications

Hearth and Home Technologies has consistently pushed the boundaries of modern heating solutions, and their SL-550TR-D, SL-750TR-D, and SL-950TR-D gas fireplace inserts are prime examples of this innovation. Designed to enhance both the aesthetic appeal and functionality of any living space, these units are ideal for homeowners seeking efficient, reliable heating without sacrificing style.

Starting with the SL-550TR-D, this model features a compact design that is perfect for smaller rooms while still delivering impressive heat output. With a BTU range of 25,000, it efficiently warms spaces without overwhelming them. The SL-550TR-D uses advanced combustion technology, ensuring a clean and efficient burn that minimizes emissions. The large viewing area, complemented by a contemporary linear design, allows for an unobstructed flame view, making it an attractive centerpiece in any room.

Moving on to the SL-750TR-D, this insert expands on the features of the SL-550TR-D, with a higher BTU output of 35,000, making it suitable for larger spaces or homes in colder climates. It also includes an adjustable flame height feature, allowing users to customize the ambiance and heat level to their liking. Additionally, the SL-750TR-D comes equipped with a remote control, providing convenience and ease of use. Its sleek design and modern aesthetics make it an appealing choice for contemporary home settings.

Finally, the SL-950TR-D takes efficiency and style to the next level with a robust BTU output of 45,000. This model is designed for maximum warmth and efficiency, catering to expansive living areas. Its enhanced airflow management system ensures even heat distribution throughout the space. Moreover, the SL-950TR-D offers customizable options such as LED lighting, creating a stunning visual effect that complements the flickering flames.

All three models are equipped with Hearth and Home Technologies' patented Power Vent technology, allowing for flexible installation options, even in challenging spaces. This system provides the ability to vent vertically or horizontally, granting homeowners the freedom to optimize their fireplace's location.

In conclusion, the SL-550TR-D, SL-750TR-D, and SL-950TR-D gas fireplace inserts offer unparalleled heating solutions tailored to various needs and preferences. Their combination of high efficiency, elegant design, and user-friendly features make them standout choices for anyone looking to enhance their home’s comfort and style.