Hearth and Home Technologies SL-550TR-D Reference Materials, Appliance Dimension Diagram

Page 59

16 Reference Materials

A. Appliance Dimension Diagram

Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3.

 

 

P

 

 

 

 

 

 

 

Q

 

O

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

N

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

GAS LINE

 

Ø S

 

 

 

Ø L

 

 

 

 

 

 

 

 

ACCESS

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

T

C X

 

 

E F

G

J

 

U

 

 

 

 

 

I

 

 

 

 

 

 

 

 

V

 

B

 

W

 

ELECTRICAL

 

 

A

 

H

 

 

 

 

 

ACCESS

 

 

 

 

 

 

 

 

SL-550-TR-D

SL-750-TR-D

SL-950-TR-D

 

Location

Inches

Millimeters

Inches

Millimeters

Inches

Millimeters

 

A

36

913

40-7/8

1039

48

1218

 

B

31

790

36-1/8

917

43

1092

 

C

n/a

n/a

35-3/4

908

39-5/8

1006

 

D

18

457

21-1/2

546

23-1/2

597

 

E

17-1/4

438

20-3/4

526

22

559

 

F

31-1/8

790

34-5/8

879

38-9/16

980

 

G

3-9/16

90

3-9/16

90

3-9/16

90

 

H

6-7/8

174

6-7/8

174

6-7/8

174

 

I

35-1/2

902

40

1016

44

1118

 

J

31-9/16

828

37-7/8

962

41-7/8

1063

 

K

23-3/8

594

26-7/8

683

30-7/8

784

 

L

8

203

8

203

8

203

 

M

8-13/16

223

8-13/16

223

8-13/16

223

 

N

16-1/4

414

16-1/4

413

16-1/4

414

 

O

1/2

13

1/2

13

1/2

13

 

P

25-3/4

653

30-3/4

781

37-5/8

956

 

Q

12-7/8

326

15-3/8

391

18-7/8

478

 

R

15-7/8

403

15-7/8

403

15-11/13

406

 

S

6-5/8

168

6-5/8

168

6-5/8

168

 

T

n/a

n/a

n/a

n/a

n/a

n/a

 

U

2-3/16

55

2-3/16

55

2-3/16

55

 

V

6

152

6

152

6

152

 

W

1

25

1

25

1

25

 

X

30-1/8

765

34-7/8

886

37-11/16

957

 

Figure 16.1 Appliance Dimensions

 

 

 

 

 

 

 

Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/06

59

 

 

 

 

 

 

 

Image 59
Contents What to do if you smell gas Models SL-550TR-D SL-750TR-D SL-950TR-DHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsModels Framing and ClearancesSelecting Appliance Location Clearances Constructing the Appliance ChaseClearances to Mantels or other Combustibles above Appliance Mantel ProjectionsSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Minimum Clearances for Termination Alcove ApplicationsMeasuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsUse of Flex Vent Top Vent Horizontal Termination Venting with 1 elbow NG Vent DiagramsMinimum Top Vent Horizontal Termination Venting with 2 elbows NGTop Vent Horizontal Termination Venting with 3 elbows NG Components only Baffle InstructionTop Vent Vertical Termination Venting with 2 elbows Propane Top Vent Vertical Termination Venting with 2 elbows NGTop Vent Vertical Termination Venting with 3 elbows Propane Top Vent Vertical Termination Venting with 3 elbows NGH1 = 9 in mm Maximum Rear Vent Horizontal Termination Venting with 3 elbows Rear Vent Horizontal Termination Venting with 2 elbowsRear Vent Vertical Termination Venting with 2 elbows Rear Vent Vertical Termination Venting with 1 elbowV1 MIN H1 MAX H2 MAX Rear Vent Vertical Termination Venting with 3 elbowsNon-Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Choosing the Top or Rear Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear VentFire Risk Prevent contact with sagging, loose insulation Securing and Leveling the ApplianceAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections DVP Pipe only Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsDVP Pipe only Securing the Vent Sections Vertical SectionsContinue Adding Vent Components Assembly of Vent Sections SL Series Pipe onlyInstall Support Brackets Attach the First Vent Component to Starting CollarsHeat Shield Requirements for Horizontal Termination Installing the Horizontal Termination CapFire Risk. Explosion Risk 16 Minimum Height from Roof to Lowest Discharge Opening Installing Roof Flashing and Vertical Termination Cap19 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireConnecting to the Appliance Intellifire Ignition System Wiring Standing Pilot Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationSee for combustible/non-combustible definitions FinishingFacing Material Remove Shipping Materials Appliance SetupClean the Appliance AccessoriesPositioning the Logs Log Set Assembly LOGS-SL550-D Models SL-550TR-DTAB Locator Log Set Assembly LOGS-SL750-D Models SL-750TR-D, SL-950TR-D Notches Raised Flat Spots Shutter Settings Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore Lighting Appliance Operating InstructionsThis appliance is equipped with an ignition Turn off all electric power to the applianceTurn on all electric power to the appliance Lighting ApplianceStanding Pilot Ignition For Your Safety Read Before Lighting InstructionsAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingSympton Possible Cause Corrective Action Intellifire Ignition SystemSure must not exceed 14 in. W.C Maintaining and Servicing Appliance Recommend addition of screen if one is not present Inspect Maintenance TasksReference Materials Appliance Dimension DiagramDVP45 45 Elbow Vent Components DiagramsDVP-TRAP 356 mm 13-1/4367 mm 13-7/8 352 mm 241 mmVertical Termination Cap High wind 98 mm10-1/2 Vertical Termination Cap 184 mm 12-1/2 318 mm 133 mmPipe Length/Inches SL Series Vent ComponentsLog Set Assembly Service PartsAdditional service part numbers may appear on the following Service Parts List215 SL-750TR-DSL-750TR-D Additional service part numbers may appear on the following216 SL-950TR-DService Parts List Intermittent Pilot Ignition SL-550 / 750 / 950TR-D-IPISL-550 / 750 / 950TR-D Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information

SL-950TR-D, SL-750TR-D, SL-550TR-D specifications

Hearth and Home Technologies has consistently pushed the boundaries of modern heating solutions, and their SL-550TR-D, SL-750TR-D, and SL-950TR-D gas fireplace inserts are prime examples of this innovation. Designed to enhance both the aesthetic appeal and functionality of any living space, these units are ideal for homeowners seeking efficient, reliable heating without sacrificing style.

Starting with the SL-550TR-D, this model features a compact design that is perfect for smaller rooms while still delivering impressive heat output. With a BTU range of 25,000, it efficiently warms spaces without overwhelming them. The SL-550TR-D uses advanced combustion technology, ensuring a clean and efficient burn that minimizes emissions. The large viewing area, complemented by a contemporary linear design, allows for an unobstructed flame view, making it an attractive centerpiece in any room.

Moving on to the SL-750TR-D, this insert expands on the features of the SL-550TR-D, with a higher BTU output of 35,000, making it suitable for larger spaces or homes in colder climates. It also includes an adjustable flame height feature, allowing users to customize the ambiance and heat level to their liking. Additionally, the SL-750TR-D comes equipped with a remote control, providing convenience and ease of use. Its sleek design and modern aesthetics make it an appealing choice for contemporary home settings.

Finally, the SL-950TR-D takes efficiency and style to the next level with a robust BTU output of 45,000. This model is designed for maximum warmth and efficiency, catering to expansive living areas. Its enhanced airflow management system ensures even heat distribution throughout the space. Moreover, the SL-950TR-D offers customizable options such as LED lighting, creating a stunning visual effect that complements the flickering flames.

All three models are equipped with Hearth and Home Technologies' patented Power Vent technology, allowing for flexible installation options, even in challenging spaces. This system provides the ability to vent vertically or horizontally, granting homeowners the freedom to optimize their fireplace's location.

In conclusion, the SL-550TR-D, SL-750TR-D, and SL-950TR-D gas fireplace inserts offer unparalleled heating solutions tailored to various needs and preferences. Their combination of high efficiency, elegant design, and user-friendly features make them standout choices for anyone looking to enhance their home’s comfort and style.