D. Install Back Molded Brick Panel-Herring- bone
•Remove Screen Rods
•Remove Smokeshield
•Refer to Figure 11.2.
•Set the grate brackets in place, 26.5 in. (673 mm) center to center.
•Install the back panel. Center from side to side.
•Install two
E. Install Side Molded Brick Panel-Herring- bone
•If a gas line is to be installed, remove the knockouts in the inner firebox and in the outer shell on the side of your choice. Refer to dimension drawings for location of knockouts and Section 13.A. for gas provisions.
•Install side panel, tapered edge to the front. Align the front edge with the front of the column (or butted to the surround if installed).
•Install two
•Install second side panel following the steps above.
•Replace the smokeshield.
Back Herringbone Refractory
LH Herringbone Refractory
Refractory clip
Hearth
Figure 11.2 Herringbone Molded Brick Panel
Heatilator • Birmingham | 37 |