Hearth and Home Technologies BIR50-B Finishing, Hearth Extension, = 1/k x inches of thickness

Page 39

12 Finishing

A. Non-combustible Materials

Materials which will not ignite and burn, composed of any combination of the following:

-

Steel

-

Iron

-

Brick

-

Tile

-

Concrete

-

Slate

-

Glass

-

Plasters

Materials reported as passing ASTM E 136, Standard

Test Method for Behavior of Metals, in a Vertical Tube Furnace at 750° C

B. Combustible Materials

Materials made of or surfaced with any of the following materials:

-

Wood

-

Compressed paper

-

Plant fibers

-

Plastic

Any material that can ignite and burn; flame proofed or not, plastered or un-plastered

C. Hearth Extension

WARNING! Risk of fire! High temperatures, sparks, em- bers or other burning material falling from the fireplace may ignite flooring or concealed combustible surfaces.

Metal hearth strips MUST be installed (Section 7.C.).

Hearth extensions MUST be installed exactly as specified.

You MUST use a hearth extension with this fireplace.

This fireplace has been tested and approved for use with a hearth extension insulated to a minimum R value of 2.32.

The hearth extension material MUST be covered with tile, stone or other non-combustible material.

Manufactured hearth materials will usually have a published R value (resistance to heat) or k value (conductivity of heat). Refer to the formula in Table 12.1 to convert a k value to an R value,

Refer to Table 12.2 for hearth extension insulation alternatives.

12in.

(305 mm)

50 in.

12 in.

(1270 mm)

(305 mm)

 

Table 12.1

R = 1/k x inches of thickness

74 in.

(1880 mm)

(R value of hearth must be equal to or greater than 2.06)

20 in. (508 mm) Minimum

Figure 12.1 Standard Hearth Extension Dimensions

Table 12.2

Hearth Extension Insulation Alternatives-Total minimum R Value must equal 2.06

 

k per inch

R per inch

 

Material

thick

thick

Minimum thickness required

Hearth & Home HX3, HX4

0.49

2.06

1 1/2 in. (38 mm)

 

 

 

 

USG Micore 300™

0.49

2.06

1 in.(25.4 mm)

USG Durock™ Cement Board

1.92

0.52

4 1/2 in. (114 mm)

Cement Mortar

5.0

0.20

11 5/8 in. (295 mm)

 

 

 

 

Common Brick

5.0

0.20

11 5/8 in. (295 mm)

Ceramic Tile

12.50

0.08

29 in. (737 mm)

 

 

 

 

Armstrong™ Privacy Guard Plus

0.46

2.18

1 1/2 in. (38 mm)

Marble

14.3 to 20.0

0.07 to 0.05

33 to 46 1/2 in. (838 to 1181 mm)

Heatilator • Birmingham BIR50-B4059-682C• 8/12

39

Image 39
Contents Fire Risk Hot screen/mesh and glass doors will cause burnsHeatilator Birmingham BIR50-B 4059-682C 8/12 Listing Label Information/LocationGrate NumberTable of Contents Installer GuideUser Guide Limited Lifetime Warranty WarrantyWarranty Conditions Combustible Materials Listing and Code ApprovalsAppliance Certification Non-combustible MaterialsYour Fireplace Operating InstructionsFirescreen Seasoned WoodStarting a Fire GrateClear Space Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsHardwood vs Softwood Wood FuelMaintainance and Service Chimney Inspection/CleaningDisposal of Ashes Frequency As desired Glass CleaningCheck Firebox Molded Brick Panel Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDesign and Installation Considerations DraftNegative Pressure Windward Locating your Fireplace & ChimneyTypical Fireplace Components Tools and Supplies Needed Inspect Fireplace and ComponentsFraming & Clearances Select Fireplace LocationModel # Air Space Clearances ClearancesFrame the Fireplace Sidewalls/SurroundsPlace Protective Metal Hearth Strips Installation of FireplaceThings to Consider Position the FireplaceYES Install Outside Air KitChimney Requirements Chimney AssemblyEffective Cut Roof Opening Installation NotesInstall Firestop Frame OpeningsAssemble Chimney Sections Using Offsets/ReturnsSupplementary Support & Stabilizer Offset Elbow InstallationInstall Attic Insulation Shield Install Roof Radiation ShieldsAttach Flashing Field-Constructed Chase Top Flashing Finish Top Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsShroud Requirements ShroudsHouse Style Shroud House Style Shroud Minimum DimensionsPyramid Style Shroud Arch / Mailbox Style Shroud Install Side Molded Brick Panel-Traditional Installation of Molded Brick Panel Install Hearth Molded Brick Panel Install Back Molded Brick Panel-TraditionalInstall Side Molded Brick Panel-Herring- bone Install Back Molded Brick Panel-Herring- boneInstall Mortar Optional Install ScreensFinishing Hearth Extension= 1/k x inches of thickness Raised Hearth Extension Framing Decorative Facing Finishing MaterialStandoffs Combustible MantelFlush Front Gas Code, Ansi Z223.1 AccessoriesGas Log/Lighter Provision Wood Burning InsertsReference Materials Fireplace DimensionsRequired/shipped separately Chimney Components50 in. Woodburning Fireplace Service PartsStocked At DepotTraditional Refractory Traditional RefractoryHerringbone Refractory This page intentionally left blank Contact Information