A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 B. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 B. Tempered Glass Specifications . . . . . . . . . . . . . . . . . . . . . 7 C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 7 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 7 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 7 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 H. Requirements for the Commonwealth of Massachusetts. . 8

User Guide

2 Operating Instructions

A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 C. Fan Kit (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 D. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 E. Decorative Doors and Fronts . . . . . . . . . . . . . . . . . . . . . . 10 F. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 G. Remote Controls, Wall Controls and Wall Switches. . . . . 10 H. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . 10 I. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 11 J. After Fireplace is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 K. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 12

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 13 B. Maintenance Tasks-Qualified Service Technician . . . . . . 14

Installer Guide

4 Getting Started

A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 16

B. Design and Installation Considerations . . . . . . . . . . . . . . 17

C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 17

D. Inspect Appliance and Components. . . . . . . . . . . . . . . . . 17

5 Framing and Clearances

A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . 18

B. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . 19

C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

D. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 20

6 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 21

7 Vent Information and Diagrams

A. Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

B. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

C. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

D. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

E. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 28 B. Wall Penetration Framing. . . . . . . . . . . . . . . . . . . . . . . . . 29 C. Install the Ceiling Firestop . . . . . . . . . . . . . . . . . . . . . . . . 30 D. Install Attic Insulation Shield. . . . . . . . . . . . . . . . . . . . . . . 31

9 Appliance Preparation

A. Attaching Sheetrock Ledges . . . . . . . . . . . . . . . . . . . . . . 32

B. Temporary Access Panel. . . . . . . . . . . . . . . . . . . . . . . . . . 32

C. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 33

D. Installing the Fiberglass Gasket . . . . . . . . . . . . . . . . . . . . 33

E. Completing Grate Set-up . . . . . . . . . . . . . . . . . . . . . . . . . 34

F. Checking Pilot Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

10 Installing Vent Pipe

A. Assemble Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . . 35 B. Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 36 C. Secure the Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . 36 D. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 37 E. Install Metal Roof Flashing. . . . . . . . . . . . . . . . . . . . . . . . 38 F. Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . . 38 G. Install RF4-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 H. Install Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . 40 I. Heat Shield Requirements for Horizontal Termination . . . 40 J. Install Horizontal Termination Cap . . . . . . . . . . . . . . . . . . 41

11 Gas Information

A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 42

12 Electrical Information

A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 B. Intellifire Ignition System Wiring . . . . . . . . . . . . . . . . . . . . 43 C. Optional Accessories Requirements . . . . . . . . . . . . . . . . 43 D. Electrical Service and Repair . . . . . . . . . . . . . . . . . . . . . . 44 E. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 45 F. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 45

Heat & Glo • 8000CF-OAK-IPI2059-900 Rev. Q • 11/08

3

Image 3
Contents What to do if you smell gas HOT SurfacesHot glass will cause burns Congratulations Homeowner Reference InformationXxxxxxxx User Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalGAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASFrequently Asked Questions Issue SolutionsAfter Fireplace is Lit Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingEither cobrahead or SIT Typical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesMinimum Framing Dimensions Constructing the Appliance ChaseClearances Mantel and Wall Projections Combustible MantelsCombustible Mantel Legs or Wall Projections Vent Termination Minimum Clearances Termination Locations= Vent Terminal = AIR Supply Inlet = Area Where Terminal is not PermittedUse of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyV1 Minimum H1 + H2 Maximum Vent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows V1 Minimum H1 MaximumV1 Min H1 Max V2 Min H2 Max V1 + V2 Min H1 + H2 Max Top Vent Horizontal Termination Three ElbowsVertical Top Vent ChartTop Vent Vertical Termination Two Elbows H1 Maximum V1 + MinimumH1+ H2 V1+ V2 Minimum H1+ H2 Maximum Required Vent Clearances and FramingPipe Clearances to Combustibles Heat Shield Above First 900 ElbowWall Penetration Framing Combustible Wall PenetrationNon-Combustible Wall Penetration Pipe DVP Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Temporary Access Panel Appliance PreparationAttaching Sheetrock Ledges Securing and Leveling the Appliance Installing the Fiberglass GasketChecking Pilot Plate Completing Grate Set-upAssemble Pipe Sections Installing Vent PipeAttach Vent to the Firebox Assembly Assemble Vent SectionsSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections 10 Rotate Seams for DisassemblyAssemble and Install Storm Collar Install Metal Roof FlashingApply Sealant TOP & Partial Sides Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapAnsi Z223.1 and CAN/CGA-B149 installation codes Install Horizontal Termination CapGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntellifire Ignition System Wiring Optional Accessories RequirementsIntellifire Pilot Ignition IPI Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Ember Placement Install the Optional RefractoryInstall the Log Assembly Log Assembly LOGS-8OAKHeat & Glo 8000CF-OAK-IPI 2059-900 Rev. Q 11/08 Air Shutter Settings Install the MeshInstall Trim and/or Surround Air Shutter SettingTroubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsLocation Inches Millimeters DVP vent components Vent Components DiagramsHorizontal Termination Cap DVP-TRAPCOOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFL305 mm DVP-TB1Service Parts Log Set AssemblyAt Depot Service Parts ListStocked Valve AssemblyContact Information

8000CF-OAK-IPI, 8000CFLP-OAKIPI specifications

Hearth and Home Technologies (HHT) is recognized for its commitment to quality and innovation in the fireplace and home heating industry. Among its popular products are the 8000CFLP-OAKIPI and 8000CF-OAK-IPI gas fireplaces, which stand out in terms of design, features, and efficiency.

The 8000CFLP-OAKIPI is a contemporary linear gas fireplace that features a stunning design suitable for modern living spaces. With its expansive viewing area, the 8000CFLP-OAKIPI provides a captivating flame presentation that transforms any room into a cozy retreat. Its clean face design eliminates a bulky frame, giving the appearance of a window to the flames. This model is equipped with LED accent lighting that enhances the ambiance further when the fireplace is not in use.

On the other hand, the 8000CF-OAK-IPI offers a more traditional design that features a classic fireplace experience while incorporating modern technology. It uses high-efficiency gas combustion to deliver unmatched warmth while ensuring minimal emissions. Both models come with the option for ceramic fiber logs, which mimic the natural look of real wood while enhancing heat production.

The advanced IntelliFire app supports both units, allowing users to control the fire conveniently via smartphone or tablet. This technology offers increased functionality, enabling users to adjust flame height, fan speed, and lighting settings for the perfect ambiance.

In terms of energy efficiency, both the 8000CFLP-OAKIPI and the 8000CF-OAK-IPI are designed to offer significant savings on heating bills. They are equipped with an electronic ignition system that offers seamless startup and optimal combustion efficiency. The design also adheres to stringent efficiency standards, ensuring that users enjoy a sustainable and cost-effective heating solution.

Installation is made straightforward with their versatile venting options, allowing for both direct vent and vent-free configurations. This flexibility ensures compatibility with various home layouts while optimizing heat distribution.

In summary, the Hearth and Home Technologies 8000CFLP-OAKIPI and 8000CF-OAK-IPI gas fireplaces represent a blend of style, technology, and efficiency. With their focus on innovation and customer satisfaction, HHT continues to lead the way in providing modern heating solutions that elevate any living space.