Baxi Potterton 24 Eco HE Legislation, Important Installation, Commissioning, Service & Repair

Page 4

IMPORTANT - Installation, Commissioning, Service & Repair

This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance.

In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations.

Definition of competence: A person who works for a CORGI registered company and holding current certificates in the relevant ACS modules, is deemed competent.

In IE, this must be carried out by a competent person as stated in I.S. 813 “Domestic Gas Installations”.

Lifting - This product should be lifted and handled by two people. Stooping should be avoided and protective equipment worn where necessary. Carrying & lifting equipment should be used as required, e.g. when installing in a loft space.

The addition of anything that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations.

Warning - Check the information on the data plate is compatible with local supply conditions.

LEGISLATION

Potterton declare that no substances harmful to health are contained in the appliance or used during appliance manufacture.

The appliance is suitable only for installation in GB and IE and should be installed in accordance with the rules in force, and only used in a suitably ventilated location.

In GB, the installation must be carried out by a CORGI Registered Installer. It must be carried out in accordance with the relevant requirements of the:

Gas Safety (Installation & Use) Regulations.

The appropriate Building Regulations either The Building Regulations, The Building Regulations (Scotland), Building Regulations (Northern Ireland).

The Water Fittings Regulations or Water Byelaws in Scotland.

The Current I.E.E. Wiring Regulations.

Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice.

In IE, the installation must be carried out by a competent Person and installed in accordance with the current edition of I.S. 813 ‘Domestic Gas Installations’, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation.

All systems must be thoroughly flushed and treated with inhibitor (see section 6.2).

All CORGI registered installers carry a CORGI identification card and have a registration number. You can check your installer is registered by telephoning 0870 4012300 or writing to:-

1Elmwood, Chineham Business Park,

Crockford Lane,

Basingstoke. RG24 8WG

or check online at www.corgi-gas-safety.com

Codes of Practice, most recent version should be used

In GB the following Codes of Practice apply:

Standard

Scope

BS 6891

Gas Installation.

BS 5546

Installation of hot water supplies for

 

domestic purposes.

BS 5449

Forced circulation hot water systems.

BS 6798

Installation of gas fired hot water boilers.

BS 5440 Part 1

Flues.

BS 5440 Part 2

Ventilation.

BS 7074

Expansion vessels and ancillary equipment

 

for sealed water systems.

BS 7593

Treatment of water in domestic hot water

 

central heating systems.

In IE the following Codes of Practice apply:

Standard

Scope

I.S. 813

Domestic Gas Installations.

The following BS standards give valuable additional information;

BS 5546

Installation of hot water supplies for

 

domestic purposes.

BS 5449

Forced circulation hot water systems.

BS 7074

Expansion vessels and ancillary equipment

 

for sealed water systems.

BS 7593

Treatment of water in domestic hot water

 

central heating systems.

4

Publication No. 5111811

Image 4
Contents Performa Contents Installer Notification Guidelines Scheme Members onlyImportant Installation, Commissioning, Service & Repair LegislationDescription IntroductionOptional Extras General Layout LayoutCentral Heating Mode Fig Domestic Hot Water Mode FigAppliance Operation Central Heating Circuit KeyTechnical Data Dimensions and Fixings Gas Inlet 68mm95mm 65mm Left Hand Side 130mm BoilerSystem Details InformationCentral Heating Circuit BypassExpansion Vessel Central Heating only System Filling and PressurisingPressure Relief Valve Fig Showers Domestic Hot Water CircuitHard Water Areas Site Requirements LocationGas Supply Ventilation of CompartmentsElectrical Supply Condensate Drain Flue Likely flue positions requiring Flue terminal guardFlue Dimensions Flue TrimTerminal Guard Fig Maximum permissible flue length is 4 metresHorizontal Flues Vertical Twin Pipe Flue OptionsInstallation Initial PreparationFlushing Preparing The BoilerFitting The Boiler Fitting the Pressure Relief Discharge Pipe FigCondensate Drain see section Fitting The FlueVertical Flue Functional Flow Diagram Key to WiringMaking The Electrical Connections Preliminary Electrical ChecksCommissioning Commissioning the BoilerAdjusting the Pressure Fig Checking the Burner PressureCompletion CompletionServicing the Boiler 11 .1 Annual ServicingW. Filters Fig Annual ServicingInlet / Return Manifold Pressure Switch Fig Changing ComponentsHeat Exchanger Fig Burner FigElectrodes Fig Injectors FigInsulation Fig Safety Thermostat Fig Temperature Sensor FigGas Valve Fig Pump Complete Figs Pump Head Only FigsAutomatic Air Vent Fig Expansion Vessel Fig Pressure Gauge FigsCondensate Trap Fig Selector Switch Fig 12.18 P.C.B. FigDiverter Valve Assembly Fig Plate Heat Exchanger FigSeals DHW Pressure Differential Valve FigDiverter Valve Assembly CH Pressure Microswitch FigFlow Regulator Figs CH Pressure Differential Valve FigSecondary Heat Exchanger Fig Flue Overheat Thermostat FigElectrical Illustrated Wiring DiagramControl PCB Short Parts List Short Parts ListCarry out initial fault finding checks Fault FindingOperation sequence Correct Operation sequence Fault Finding Solutions Sections a to E Fault Finding PCB GAS Boiler Commissioning Checklist Service 1 Date Service 3 DateService 5 Date Service 7 DateService GB General Enquiries GBTechnical GB Literature Request GB

24 Eco HE specifications

The Baxi Potterton 24 Eco HE is a highly efficient and reliable boiler designed to meet the heating and hot water needs of modern homes. This wall-mounted combination boiler is particularly suited for smaller properties, providing a compact solution without compromising on performance.

One of the standout features of the Baxi Potterton 24 Eco HE is its high efficiency rating. It boasts an impressive ErP A-rating for both heating and hot water, which indicates that it is designed to minimize energy consumption and reduce utility bills. The condensing technology employed in this boiler recovers heat from flue gases that would otherwise be lost, optimizing the overall energy use and enhancing its eco-friendly credentials.

The Baxi Potterton 24 Eco HE also incorporates an intelligent control system, allowing homeowners to manage their heating settings more effectively. The built-in digital display is user-friendly, providing easy access to information such as system pressure and temperature settings. This feature facilitates easy programming of heating schedules, helping to ensure comfort while optimizing energy use.

Another characteristic of the Baxi Potterton 24 Eco HE is its impressive hot water output. With a hot water flow rate of up to 10.2 liters per minute, it ensures that showers and taps can be used simultaneously without running out of hot water. This makes it an excellent choice for families or households where demand for hot water is high.

Furthermore, the compact design of the Baxi Potterton 24 Eco HE allows for flexible installation options. Its reduced size means it can fit easily in kitchen cupboards or other confined spaces, making it ideal for homes where space is at a premium.

The boiler is equipped with a low-energy pump and a built-in frost protection feature, ensuring reliable operation even in colder climates. Additionally, its quiet operation contributes to a more comfortable living environment.

In summary, the Baxi Potterton 24 Eco HE is an efficient, compact, and powerful boiler that caters to the demands of modern living. With features such as high efficiency, intelligent controls, impressive hot water delivery, and flexible installation options, it stands out as a top choice for homeowners seeking a dependable and eco-friendly heating solution. This boiler is a testament to Baxi's commitment to delivering quality and innovation in the heating sector.