Baxi Potterton 24 Eco HE manual Technical Data

Page 8

4.0TECHNICAL DATA

Appliance Type

C12

C32

Appliance Category

CAT II 2H 3P

Heat Input CH

 

 

 

 

 

Max

Min

 

kW

24.8

 

10.6

 

Heat Output CH (Non-Condensing)

Max Min

kW 24 9.8

Heat Output CH (Condensing)

Max Min

kW 25.2 10.1

Heat Input DHW

Max

kW 24.8

Heat Output DHW

Max

kW 24

Max Gas Rate (Natural Gas - G20) (After 10 mins)

m3/h 2.62

Burner Pressure (Natural Gas - G20)

 

 

Max Rate

Min Rate

 

mbar

10.2 ± 0.5

2 ± 0.2

 

 

 

 

 

 

 

 

 

Inlet Pressure (Natural Gas - G20)

 

mbar

20

 

 

 

 

 

 

 

 

Burner Injector (Natural Gas - G20)

 

15 x 1.18mm Diameter

 

 

 

 

 

 

 

 

 

Electrical Supply

 

 

 

230V~ 50Hz

 

(Appliance must be connected to an

 

earthed supply)

 

 

 

 

 

 

 

 

 

 

Power Consumption

170W

 

 

 

 

 

 

 

External Fuse Rating

3A

 

 

Internal Fuse Rating

Fuse 2A Fast Blow to BS 4265

Electrical Protection

 

IPX4D

 

 

 

 

 

 

 

 

NOx Class

 

 

 

3

 

 

Condensate Drain

1” BSP

 

 

 

 

 

 

 

 

 

Flue Terminal

 

Diameter

100mm

Dimensions

 

Projection

125mm

 

 

 

 

 

 

 

 

Connections

 

 

 

copper tails

Gas Supply

 

 

 

-

22mm

Central Heating Flow

-

22mm

Central Heating Return

-

22mm

Cold Water Mains Inlet

-

15mm

DHW Flow

 

 

 

-

15mm

Pressure Relief Discharge

-

15mm

 

 

 

 

 

 

 

 

 

Outercase Dimensions

 

 

 

Casing Height

 

 

 

-

780mm

Overall Height Inc Flue

 

 

 

Elbow

 

 

 

-

965mm

Casing Width

 

 

 

-

450mm

Casing Depth

 

 

 

-

345mm

 

 

 

 

 

 

 

 

 

 

Clearances

 

 

 

 

 

 

Above Casing

 

200 mm Min

 

 

Below Casing

 

200 mm Min

 

 

Front

 

450 mm Min (For Servicing)

Front

 

5 mm Min (In Operation)

L.H. Side

 

5 mm Min

 

 

R.H. Side

 

5 mm Min (In Operation)

 

 

 

 

 

20 mm Min (See Note*)

*NOTE: The boiler can be operated with a clearance of 5mm at the right. This is also sufficient for routine maintenance.

However a clearance of 20mm is required if it is necessary to remove the secondary heat exchanger. This should be considered when siting the appliance and in the event of any subsequent alterations in the area of installation

Weights

kg

Packaged Boiler Carton

50

Installation Lift Weight

43.5

Central Heating Primary Circuit

Pressures

 

 

 

bar

Safety Discharge

3

Max Operating

2.5

Min Operating

0.5

Recommend Operating

1-2

 

 

 

DHW Circuit

bar

Pressures

 

Max Operating

8

Min Operating

0.2

Min Operating Pressure

 

at 11.1 l/min

0.9

 

 

 

Flow Rates

l/min

DHW Flow Rate

 

@ 30°C Rise

11.5

DHW Flow Rate

 

@ 35°C Rise

9.8

Min Working

 

DHW Flow Rate

2.5

Pump

Available Head See graph below

Expansion Vessel - (For Central Heating only. Integral with appliance)

 

bar

Min Pre-charge Pressure

0.5

 

litre

Max Capacity of

 

CH System

125

Primary Water Content

1.0

of Boiler (unpressurised)

 

Temperatures

C.H. Flow Temp (adjustable)

35°C to 85°C max (± 5°C)

D.H.W. Flow Temp

35°C to 65°C max (± 5°C) dependent upon flow rate

SEDBUK Declaration For Performa 24 Eco HE

The seasonal efficiency (SEDBUK) is 87.3% (89.3% LPG)

Band B

This value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from which it has been calculated have been certified by 0051.

LPG Propane - G31

Burner Injector 15 x 0.77mm diameter

Burner Pressure

Max Rate

Min Rate

 

Propane

mbar

21.8 ± 0.5

4.4 ± 0.2

 

 

 

 

 

Inlet Pressures

 

 

 

mbar

 

37

 

 

Metre (wg)

Pump - Available Head

5

4.5

4

3.5

3

2.5

2

1.5

1

0.5

0

0

200

400

600

800

1000

1200

Flow Rate (l/h)

8

Publication No. 5111811

Image 8
Contents Performa Contents Installer Notification Guidelines Scheme Members onlyImportant Installation, Commissioning, Service & Repair LegislationOptional Extras IntroductionDescription General Layout LayoutCentral Heating Mode Fig Domestic Hot Water Mode FigAppliance Operation Central Heating Circuit KeyTechnical Data Dimensions and Fixings Gas Inlet 68mm95mm 65mm Left Hand Side 130mm BoilerSystem Details InformationCentral Heating Circuit BypassPressure Relief Valve Fig System Filling and PressurisingExpansion Vessel Central Heating only Hard Water Areas Domestic Hot Water CircuitShowers Site Requirements LocationElectrical Supply Ventilation of CompartmentsGas Supply Condensate Drain Flue Likely flue positions requiring Flue terminal guardFlue Dimensions Flue TrimTerminal Guard Fig Maximum permissible flue length is 4 metresHorizontal Flues Vertical Twin Pipe Flue OptionsInstallation Initial PreparationFlushing Preparing The BoilerFitting The Boiler Fitting the Pressure Relief Discharge Pipe FigCondensate Drain see section Fitting The FlueVertical Flue Functional Flow Diagram Key to WiringMaking The Electrical Connections Preliminary Electrical ChecksCommissioning Commissioning the BoilerAdjusting the Pressure Fig Checking the Burner PressureCompletion CompletionServicing the Boiler 11 .1 Annual ServicingInlet / Return Manifold Annual ServicingW. Filters Fig Pressure Switch Fig Changing ComponentsHeat Exchanger Fig Burner FigInsulation Fig Injectors FigElectrodes Fig Gas Valve Fig Temperature Sensor FigSafety Thermostat Fig Automatic Air Vent Fig Pump Head Only FigsPump Complete Figs Condensate Trap Fig Pressure Gauge FigsExpansion Vessel Fig Selector Switch Fig 12.18 P.C.B. FigDiverter Valve Assembly Fig Plate Heat Exchanger FigSeals DHW Pressure Differential Valve FigDiverter Valve Assembly CH Pressure Microswitch FigFlow Regulator Figs CH Pressure Differential Valve FigSecondary Heat Exchanger Fig Flue Overheat Thermostat FigControl PCB Illustrated Wiring DiagramElectrical Short Parts List Short Parts ListOperation sequence Correct Fault FindingCarry out initial fault finding checks Operation sequence Fault Finding Solutions Sections a to E Fault Finding PCB GAS Boiler Commissioning Checklist Service 1 Date Service 3 DateService 5 Date Service 7 DateService GB General Enquiries GBTechnical GB Literature Request GB

24 Eco HE specifications

The Baxi Potterton 24 Eco HE is a highly efficient and reliable boiler designed to meet the heating and hot water needs of modern homes. This wall-mounted combination boiler is particularly suited for smaller properties, providing a compact solution without compromising on performance.

One of the standout features of the Baxi Potterton 24 Eco HE is its high efficiency rating. It boasts an impressive ErP A-rating for both heating and hot water, which indicates that it is designed to minimize energy consumption and reduce utility bills. The condensing technology employed in this boiler recovers heat from flue gases that would otherwise be lost, optimizing the overall energy use and enhancing its eco-friendly credentials.

The Baxi Potterton 24 Eco HE also incorporates an intelligent control system, allowing homeowners to manage their heating settings more effectively. The built-in digital display is user-friendly, providing easy access to information such as system pressure and temperature settings. This feature facilitates easy programming of heating schedules, helping to ensure comfort while optimizing energy use.

Another characteristic of the Baxi Potterton 24 Eco HE is its impressive hot water output. With a hot water flow rate of up to 10.2 liters per minute, it ensures that showers and taps can be used simultaneously without running out of hot water. This makes it an excellent choice for families or households where demand for hot water is high.

Furthermore, the compact design of the Baxi Potterton 24 Eco HE allows for flexible installation options. Its reduced size means it can fit easily in kitchen cupboards or other confined spaces, making it ideal for homes where space is at a premium.

The boiler is equipped with a low-energy pump and a built-in frost protection feature, ensuring reliable operation even in colder climates. Additionally, its quiet operation contributes to a more comfortable living environment.

In summary, the Baxi Potterton 24 Eco HE is an efficient, compact, and powerful boiler that caters to the demands of modern living. With features such as high efficiency, intelligent controls, impressive hot water delivery, and flexible installation options, it stands out as a top choice for homeowners seeking a dependable and eco-friendly heating solution. This boiler is a testament to Baxi's commitment to delivering quality and innovation in the heating sector.