ELECTRICAL
Disconnect power before working on pump, motor, pressure switch, or wiring.
Motor Switch Settings | Dial Type Voltage Selector |
If the motor can operate at either 115 or 230 volts, it is set at the factory to 230 volts. Do not change motor voltage setting if line voltage is 230 volts, or if you have a single voltage motor.
NOTICE: Never wire a 115 volt motor to a 230 volt line.
Remove Hotor End Cover
Figure 5 - Voltage Set To 230 Volts, Dial Type
Figure 4 - Removing Motor End Cover
You will need to remove the motor end cover to change
the voltage setting. The illustration above also shows the
pressure switch. If the power supply connection still
needs to be made, the pressure svdtch cover v/ill need to be removed.
Your motor terminal board (located under the motor end cover) should look like the one at right.
To change to I 15 volts:
1.Make sure power is off.
2.Turn the dial
3.Reinstall the Motor end cover
4. Go to Wiring Connections, Page 6.
I_,WARNING] Hazardous voltage. Can shock, burn, or
kill. Connect ground wire before connecting power
supply wires. Use the wire size (including the ground
wire) specified in the wiring chart. If possible, connect the pump to a separate branch circuit with no other appli- ances on it.
[_.WARNING] Explosion hazard. Do not ground to a gas
supply line.