Table I
1.All wiring must comply with local and national electrical codes and be installed by a quatified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
2.Check available power supply and resolve any wiring
probtems BEFORE installation and operation of this unit.
3.For your safety and protection, this unit is grounded
through the power cord plug when plugged into a matching wall outtet. If you are not sure whether the well cutters in your home are propedy grounded,
please consult a qualified electrician, DO NOT USE
PLUG ADAPTERS OR EXTENSION CORD_.
4.The manufacturers nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit.
5.To avoid the possibility of personal injury, always diSConnect the power supply to the unit, before installing and/or servicing.
Suggested Individual Branch Circuit
| Nameplate Amps AWG Wire Size* | |
Dehumidifier | 5.5 | 14 |
Heater | 12,0 |
|
AWG- American Wire Gage
° Based on copper wire at 6O°C temperature rating.
Tab
| Receptacle | and Fuse | Types |
Rated'Volts | _ | 125 | |
Amps |
| 15 | |
Wall | Outlet |
|
|
Fuse | Size |
| 15 |
Time | Delay Fuse | Plug Type |
(or circuit breaker)
Dehumidifying Capacity
Etectdeal Requirements
Power input !wafts) Dehumidifier / Heatingi Rated Amperage
•Dehumidi_ing
•Heatin9
Fan (wa e)
Air Flow Circulation [Cubic Feet per Minute)
Type of Refrigerant
Water Tank Capacity
Application Area CovereSe
Operating Noise Level
Unit Dimensions Width Depth Height
Net Weight
.......,, ,,
40 Pints
115 Volts 160 Hz
563 / 1150
5.5emps
12.0amps.
35.3
141
R22
6.3litres.13.3 pints
43dBA
14 3/8, X 143t4 " X 291/2"
21.5kg / 47,3 Ib
NOTE'. Specifications are subject to change without notice, tor further improvements.