Venting (cont'd)

WARNING

fBesurevent pipeis properlyconnected to preventescapeof dangerousflue gaseswhichcouldcausedeadlyasphyxiaion;

WARNING

Chemicalvapor corrosionof the flue and vent systemmay occur if air for combustioncontainscertainchemicalvapors.

Spra ..canpropellants,.cleanin.g. solvents,refrigerator. and.air con_tmner refrigerants,swwmmmgpool chemicals,caicmm

and sodiumchloride,waxes,bleachand processchemicals aretypicalcompoundswhicharepotentiallycorrosive.

Caspiping

WARNING .......

Make sure the gassupplied is the same type listed on the modelrating plate.The inletgaspressuremustnotexceed14 incheswatercolumn[½ pound per squareinch(3.5kPa)].

WARNING

WARNING

The applianceand itsindividualshutoffvalvemustbe discon,

nectedfrom the gassupplypipingsystemduringanypressure testingof that systemat test pressuresin excessof ½ pound per squareinch(3.SkPa).

'rheappliancemustbe isolatedfrom the gassupplypiping sys. tern by closingits individualmanual shutoffvalveduring any pressuretestingof the gassupplypipingsystemat test pres- suresequalto or lessthan ½ poundpersquareinch(3.SkPa).

Use pipe joint compound or teflon tape marked as being

WARNING1

resistantto the action of petroleum [Propane(L.P.)]gases.

Connecting the gas piping to the gas control valve of the

water heater can be accomplished by either of the two methods shown.

GAS PIPING WITH FLEXIBLECONNECTOR

GAS SUPPLY PIPING

_ MANUAL SHUTOFF VALVE

if thegas controlValveis subjectedto pressuresexceeding½

poundper squareinch (3.5kPa),the damageto the gas con- trol valvecould resultin a fire or explosionfrom leakinggas.

...........WARNING ......

if the maingasline shutoffservingall gasappliancesis used, alsoturn "OFF"the gasat eachappliance.Leaveall gasappli- ancesshutoff until t-hewater heaterinstallationiscomplete.

GROUND JOINT UNION (OPTIONAL)

FLEXIgLE GAS CONNECTOR

LABELED AS COMPLYING

WITH ANSI STANDARDS

LOOP

GAS

CONTROL

VALVE

6" DRIP LEG (SEDIMENT TRAP) CAP

A gas line of sufficient size must be run to the water heater. Consult the latest edition of National Fuel Gas

Code ANSI Z223.1, also referred to as NFPA54 and the gas company concerning pipe size.

There must be:

-A readily accessible manual shut off valve in the gas sup- ply line serving the water heater, and

A drip leg (sediment trap) ahead of the gas control valve

to help prevent dirt and foreign materials from entering the gas control valve.

A flexible gas connector or a ground joint union between

the shutoff valve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting "thewater heater. Use a soapy water solution, hot a match or open flame. Rinse off soapy solution and wipe dry.

Standard Models are for installation up to 3,300 feet above sea level

High Altitude Models are for installation from 3,300 to 5,500 feet above sea level.

If astandard model is installed above 3,300 feet or a high altitude model is installed above 5,500 feet, the input rat- ing must be reduced at the rate of 4 percent for each 1,000 feet above sea level. Contact your local Sears Service Center or gas utility for further information.

The appliance and its gas connection must be leak test-

WARNING

ed before placing the appliance in operation.

GAS PIPING WITH ALL BLACK IRON PIPE TO GAS CONTROL

GAS SUPPLY PIPING

"MANUAL SHUTOFF VALVE

GROUND JOINT UNION BLACK P PE

GAS

CONTROL

T

VALVE

 

6" '

DRIP LEG

J_

(SEDIMENT TRAP)

 

 

CAP

WARNING

Contaminants in the gas lines may causeimproper opera- tion of the gascontrol-valvethat may resultin fire or explo- sion.Beforeattachingthe gasline be surethat all gaspipe is clean on the inside.To trap any dirt or foreign material in the gassupplyline, a drip leg (sometimescalled a sediment trap) mustbe incorporatedin the piping.The drip leg must be readily accessible.Install in accordancewith the "Gas Piping"section. Refer to the latest edition of the National FuelGasCode, ANSI Z223.1, alsoreferredto as NFPA54.

12

Image 12 Contents
For Your Safety Save this Manual for Future ReferenceModel Numbers Installation in Residential Areas Where Flammable J Area, as well as property damageWater heater with draft hood installed must be properly Deathseriousbodily Injuryor PropertydamageDamage High Temperature Shut Start Up ConditionsThermal Expansion OperationalType GAS RateNatural Pipe Diameter JackettopWhen Sweat Soldering Your local Sears storeDhii Additional Tools NeededWater heater. This will avoid cutting NNI Facts to Consider About LocationAllair from Inside Buildings 1Figure 3Temperature-Pressure Relief Valve SwEatcOUPLznG =Vent Pipeinstallation Water beater with draft hood installed must be ConnectFilling the Water Heater Tion, explosion or asphyxiationGAS Piping with Flexibleconnector Applianceand itsindividualshutoffvalvemustbe disconIf thegas controlValveis subjectedto pressuresexceeding½ GAS Piping with ALL Black Iron Pipe to GAS ControlInstallation Checklist Before Lighting the PilotModel Rating Plate Check for Leaks Set the thermostatto lowest settingby turningthe Whatto Doif YousmellgasControlsystemand any gas controlwhichhas been underwater Not ForceIsa thermostat setting of approximately t 30F SMOKE/ODOR Thermal ExpansionStrange Sounds Smelly WaterHigh Temperature Shut Smelly Water contdNot Enough or no HOT Water SystemBurner Cleaning Burner InspectionErty Damage Valve Operation Usethisguideto checka Leakingwater heater. Many Page SiR Sears Installation Policy