Venting (cont'd)
WARNING
fBesurevent pipeis properlyconnected to preventescapeof dangerousflue gaseswhichcouldcausedeadlyasphyxiaion;
WARNING
Chemicalvapor corrosionof the flue and vent systemmay occur if air for combustioncontainscertainchemicalvapors.
Spra ..canpropellants,.cleanin.g. solvents,refrigerator. and.air con_tmner refrigerants,swwmmmgpool chemicals,caicmm
and sodiumchloride,waxes,bleachand processchemicals aretypicalcompoundswhicharepotentiallycorrosive.
Caspiping
WARNING .......
Make sure the gassupplied is the same type listed on the modelrating plate.The inletgaspressuremustnotexceed14 incheswatercolumn[½ pound per squareinch(3.5kPa)].
WARNING
WARNING
The applianceand itsindividualshutoffvalvemustbe discon,
nectedfrom the gassupplypipingsystemduringanypressure testingof that systemat test pressuresin excessof ½ pound per squareinch(3.SkPa).
'rheappliancemustbe isolatedfrom the gassupplypiping sys. tern by closingits individualmanual shutoffvalveduring any pressuretestingof the gassupplypipingsystemat test pres- suresequalto or lessthan ½ poundpersquareinch(3.SkPa).
Use pipe joint compound or teflon tape marked as being
WARNING1
resistantto the action of petroleum [Propane(L.P.)]gases.
Connecting the gas piping to the gas control valve of the
water heater can be accomplished by either of the two methods shown.
GAS PIPING WITH FLEXIBLECONNECTOR
GAS SUPPLY PIPING
_ MANUAL SHUTOFF VALVE
if thegas controlValveis subjectedto pressuresexceeding½
poundper squareinch (3.5kPa),the damageto the gas con- trol valvecould resultin a fire or explosionfrom leakinggas.
...........WARNING ......
if the maingasline shutoffservingall gasappliancesis used, alsoturn "OFF"the gasat eachappliance.Leaveall gasappli- ancesshutoff until
GROUND JOINT UNION (OPTIONAL)
FLEXIgLE GAS CONNECTOR
LABELED AS COMPLYING
WITH ANSI STANDARDS
LOOP
GAS
CONTROL
VALVE
6" DRIP LEG (SEDIMENT TRAP) CAP
A gas line of sufficient size must be run to the water heater. Consult the latest edition of National Fuel Gas
Code ANSI Z223.1, also referred to as NFPA54 and the gas company concerning pipe size.
There must be:
A drip leg (sediment trap) ahead of the gas control valve
to help prevent dirt and foreign materials from entering the gas control valve.
A flexible gas connector or a ground joint union between
the shutoff valve and control valve to permit servicing of the unit.
Be sure to check all the gas piping for leaks before lighting "thewater heater. Use a soapy water solution, hot a match or open flame. Rinse off soapy solution and wipe dry.
Standard Models are for installation up to 3,300 feet above sea level
High Altitude Models are for installation from 3,300 to 5,500 feet above sea level.
If astandard model is installed above 3,300 feet or a high altitude model is installed above 5,500 feet, the input rat- ing must be reduced at the rate of 4 percent for each 1,000 feet above sea level. Contact your local Sears Service Center or gas utility for further information.
The appliance and its gas connection must be leak test-
WARNING
ed before placing the appliance in operation.
GAS PIPING WITH ALL BLACK IRON PIPE TO GAS CONTROL
GAS SUPPLY PIPING
"MANUAL SHUTOFF VALVE
GROUND JOINT UNION BLACK P PE
GAS
CONTROL
T | VALVE | |
| ||
6" ' | DRIP LEG | |
J_ | ||
(SEDIMENT TRAP) | ||
| ||
| CAP |
WARNING
Contaminants in the gas lines may causeimproper opera- tion of the
12