Fluke user manual Feature 566 568 Battery Life, CE Certification, Cable Length

Page 29

Infrared Thermometers

Specifications

Feature

566

 

568

 

 

 

Battery Life

12 hours with laser and backlight on; 100 hours with laser and

backlight off, at 100 % duty cycle (thermometer continuously on)

 

 

 

 

 

EN61326-1 EMC, Class B, Criteria A

 

CE Certification

EN61010-1

 

 

EN60825-1 Safety

 

 

 

 

 

Feature

K-Type Thermocouple Probe (Bead Type)

 

 

Measurement Range

-40 °C to 260 °C (-40 °F to 500 °F)

 

 

Accuracy

±1.1 °C (±2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F). Typically

within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)

 

 

 

Cable Length

1 m (40 in) K-type thermocouple cable with standard miniature

thermocouple connector and bead termination

 

 

 

21

Image 29
Contents 566/568 Limited Warranty and Limitation of Liability Table of Contents 566/568 List of Tables 566/568 List of Figures 566/568 Contacting Fluke IntroductionWWarning Safety InformationSymbols Explanation Symbols and MarkingsDisplay Language FeaturesDescription Menu OverviewSave Emissivity Menu LightMemory Material Value Min, Max, Avg, DifferentialNominal Surface Emissivity Material Value Laser AlarmTrigger Lock Backlight SetupDeleting Data LanguageOperating the Thermometer Temperature MeasurementHow the Thermometers Work Locating a Hot or Cold Spot Locating a Hot or Cold SpotDistance and Spot Size Distance and Spot SizeEmissivity Field of ViewDownloading Data Storing DataExternal Contact Probe TroubleshootingTroubleshooting Symptom Cause Action Changing the Batteries MaintenanceBattery Charge Cleaning the Lens User Replaceable Parts and AccessoriesCleaning the Housing AccessoriesRecommended Temperature Probes Specifications Feature Type Thermocouple Probe Bead Type Measurement Range Feature 566 568 Battery LifeCE Certification Cable Length566/568