CONFIGURING YOUR SYSTEM
LOCAL AREA NETWORK CONNECTION
The network IP address of the SI-1650 (both the factory default address and any address set manually using the Configuration and Setup Tool) is static and must be a unique IP address compatible with the local area network it is connecting to. Use the following steps to establish network communication between a PC, iPad or Tablet and the SI-1650 when using a local area network connection.
1.Use a Windows PC and a Direct Ethernet Connection, as described above, to initially establish communication with the SI-1650.
2.Use the Network Settings Main Selection instructions located in the on the next page of this manual to set an IP address compatible with the local area network.
3.Connect the RJ-45 network connector on the rear panel of SI-1650 to the local area network router or Ethernet Switch.
If you plan on connecting multiple SI-1650’s to a network, connect them one at a time changing each amplifier’s IP address to a unique address compatible with your network.
Warning: Never allow two or more SI-1650’s to connect to the same network with the same IP address.
Note: If necessary, the MAC ID is located on the bottom rear of the unit.