4.5 Installer Parameters Table
4.5.1 Category 1 - Room Thermostat Settings
Parameter
Parameter Factory Default Setting No.
Optional Setting
Category 1 Parameters – Room Thermostat Settings
|
| Display | Description | Display | Description |
|
|
|
|
|
|
1:CL | 24 | 24 hr clock display | 12 | 12 hr – AM/PM clock display format | |
Display |
|
| format |
|
|
|
|
|
|
|
|
Reset Time/ Temp | 2:rP | 1 | Time / Temp profile set | 0 | Time / Temperature are as programmed |
Program |
|
| to factory default |
|
|
|
|
| Changes to 0 when |
| To restore the factory profile set to 1 |
|
|
| one of the time/temp |
|
|
|
|
| profiles are changed |
|
|
|
|
|
|
|
|
Auto Summer/ | 3:tC | 1 | Auto Summer/Winter | 0 | Auto Summer/Winter Time Change |
Winter Time |
|
| Time Change Enabled |
| Disabled |
Change |
|
|
|
|
|
|
|
|
|
|
|
LCD Backlighting | 5:bL | 1 | Backlighting Enable | 0 | Backlighting Disabled |
|
|
|
|
|
|
Upper Temp Limit | 6:uL | 35 | 35°C Upper Temp. | 21 to | 21°C to 34°C adjustment in 1°C steps |
|
|
| Limit | 34 |
|
|
|
|
|
|
|
Lower Temp Limit | 7:LL | 5 | 5°C Lower Temp. Limit | 5 to 21 | 6°C to 21°C adjustment in 1°C steps |
|
|
|
|
|
|
Optimisation | 8:OP | 0 | Optimisation Disabled | 1 | Optimisation Enabled |
|
|
|
|
|
|
Temperature Offset | 12:tO | 0 | No temperature offset | ||
|
|
|
| +3 |
|
|
|
|
|
|
|
Proportional Band | 13:Pb | 1.5 | Proportional band of | 1.6 to | 1.6°C to 3.0°C adjustment in 0.1°C steps |
Width |
|
| 1.5 degrees | 3.0 |
|
|
|
|
|
|
|
Reset Parameters | 19:FS | 1 | All settings at factory | 0 | Settings are as modified above |
to Factory Defaults |
|
| defaults |
|
|
|
|
| Changes to 0 when |
| To restore the factory profile set to 1 |
|
|
| one of the parameter |
|
|
|
|
| is changed |
|
|
|
|
|
|
|
|
Notes
1)Remember to always press the green button to confirm that you want to store your new Installer Set- Up setting. To exit the Installer Mode move the slider switch to the AUTO or MAN position.
Installation Guide