Installation

Fluid pressure regulators are used for accurate, posi- tive control of the fluid pressure to spray guns, dis- pensing valves or atomizing heads.

Regulators installed at circulating line take-offs or pumps are used to reduce main line pressure and maintain the desired fluid pressure to the spray gun, dispensing valve, or atomizing head.

Installing the Fluid Regulator

1.Remove the temporary plumbing and install one regulator for each spray gun. A mounting stud, washers, and locknut are provided for mounting the regulator either from the bottom or side.

2.Put sealer on threaded connections, except on swivel unions as it interferes with the swivel action.

Before Installing the Fluid Regulator

1.Determine placement of the fluid regulator in system.

2.Install a ball valve for inlet and outlet of the regula- tor.

3.Install temporary plumbing between the ball valves.

4.Thoroughly flush the system to remove metal chips and other contaminants and to check for leaks.

3.Connect the fluid supply line to the 3/8 npt(f) inlet of the fluid regulator. Connect the fluid line be- tween the gun and the regulator’s 1/4 npt(f) outlet of choice. MAKE SURE that the direction of fluid flow agrees with the IN and OUT markings on the regulator body.

4.Flush and test the entire system.

4 306878

Image 4
Contents Instructions-Parts List Table of ContentsSymbols Equipment Misuse HazardInjection Hazard Installing the Fluid Regulator InstallationBefore Installing the Fluid Regulator Single Direct Spray Station Multiple Circulating Spray Station306878 Adjusting the Regulator Pressure Relief ProcedureOperation Maintenance CleaningRepairing FlushingParts Part NO. Description QTYPage Accessories Technical DataFluid Pressure Gauges Compression SpringsGraco Standard Warranty Graco Information