Graco 217567, 206661 Accessories, Technical Data, Fluid Pressure Gauges, Compression Springs

Page 11

Accessories

Use Only Genuine Graco Parts and Accessories

Fluid Pressure Gauges

Attaches to optional regulator outlet. 2 in. (51 mm) dial.

102397 0–3000 psi (0–21 MPa, 0–207 bar) 1/4 npt(m) center back fitting

101696 0–1000 psi (0–7 MPa, 0–70 bar) 1/4 npt(m) bottom fitting

UHMW Polyethylene U-Type Packing 108317 (included in Repair Kit 220135)

Use instead of 111796 (ref. no. 10), with abrasive fluids.

Compression Springs

NOTE: On Model 206661, standard spring 166986 (ref. no. 9) works best at 2000–3000 psi (13.5–21 MPa,135–207 bar), although it will work at 1000 to 2000 psi (7–13.5 MPa, 70–135 bar). For best results at pressures less than 2000 psi (13.5 MPa, 135 bar), order the following applicable spring.

501510 Recommended for 1000–2000 psi (7–13.5 MPa, 70–135 bar). Red color.

501511 Recommended for 0–1000 psi (0–7 MPa, 0–70 bar) range. Blue color. (Standard on model 217576)

Optional Valve Seat 206523

For use in low flow rate applications.

Technical Data

 

 

Category

Data

 

 

Maximum Fluid Inlet Pressure

3000 psi (21 MPa, 207 bar)

 

 

Regulated Fluid Pressure Range

Models 206661: 1000–3000 psi (7–21 MPa, 70–207 bar)

 

Model 217576: 200–1000 psi (1.4–7 MPa, 14–70 bar)

 

 

Maximum Flow Rate

3.5 gpm (13.25 liters/min) with 70 centipoise fluid at 75_F (23_C)

 

 

Fluid Inlet

3/8 npt(f)

 

 

Fluid Outlet (two)

1/4 npt(f)

 

 

Height

6 in. (152 mm)

 

 

Diameter

2.687 in. (68 mm)

 

 

Wetted Parts

Tungsten Carbide, Copper, Cadmium and Zinc–plated Steels, Acetal

 

Homopolymer, PTFE, Chrome–plated Stainless Steel

 

 

Canadian Registration Number (CRN):

Models 206661 and 217576

Alberta – 0C04874.52

 

Ontario – 0C4874.5R1

 

306878 11

Image 11
Contents Table of Contents Instructions-Parts ListEquipment Misuse Hazard SymbolsInjection Hazard Before Installing the Fluid Regulator InstallationInstalling the Fluid Regulator Multiple Circulating Spray Station Single Direct Spray Station306878 Operation Pressure Relief ProcedureAdjusting the Regulator Flushing MaintenanceCleaning RepairingPart NO. Description QTY PartsPage Compression Springs AccessoriesTechnical Data Fluid Pressure GaugesGraco Information Graco Standard Warranty