GE CC-SCSTAT installation manual Heat and cool schedule screen

Page 14

10

SmartCommand Thermostat Installation Manual

Heat and cool schedule screen

When you select the Heat and cool schedule menu item, the Heat and cool schedule screen (Figure 6) opens and the schedule for the current day will be displayed. Use the scroll buttons to highlight the data to be modified. Once the data has been highlighted, use the Up (+) and Down (-)buttons to change the value of the data.

To copy a day’s schedule to another day or group of days, move the cursor to C on the bottom right of the screen. When you highlight C, the button below will change from Next to Copy. Press this button to access the Copy schedule screen on page 11.

Figure 6. Heat and cool schedule screen

 

Monday Schedule

 

 

 

Time

Heat

Cool

 

Up (+)

Morn

6:00 A

72

82

+

 

Day

9:00 A

68

84

_

 

Eve

5:00 P

74

76

 

Down (-)

Nite

10:00 P

70

78

C

 

Done

 

 

 

Next

 

Done

Left

Right

Next/Copy

 

Screen navigation buttons include:

Done. Return to the Main menu screen on page 7. Left. Scroll back.

Right. Scroll forward.

Next/Copy. When the button shows Next, select the next day’s schedule. When the button shows Copy, go to the Copy schedule screen on page 11.

Up (+). Increase time or temperature. Down (-).Decrease time or temperature.

Image 14
Contents Installation Manual SmartCommand ThermostatPage Contents Contacting technical support Conventions used in this document Safety terms and symbolsPreface WDU control buttons Product overviewWall display unit WDU WDU LEDs WDU screensSetpoint display Temperature displayThermostat control screen Clock displayMenu button Mode buttonUp and down buttons Fan buttonRun/Hold button Communication error displayLED 2 green, system Economy mode display LED displayMain menu screen Done. Return to Thermostat control screen onMessages screen MessagesSchedule setup screen Schedule setup screenHeat and cool schedule screen Heat and cool schedule screenCopy schedule screen Back. Return to the Heat and cool schedule screen onUser settings screen User settings screenSet clock screen Set clock screenSensor calibration screen Sensor calibration screenBacklight display screen Backlight display screenThermostat information screen Thermostat information screenInstaller settings screen Installer settings screenNetwork settings submenu Page Installation overview Wiring overviewFreeze protection Freeze protectionMounting Wall display unit installationWiring Remote sensor connectionControl unit to Hvac wiring Control unit installationControl unit to WDU wiring Retrofit wiringHvac system wiring Standard Hvac system wiringDIP switches Hvac system 24 VAC transformerHeat pump Hvac system wiring W2/O CODIP switches Control unit connection Common or split transformer systemsRS485 address Serial communicationRS485 com port Thermostat network commands RS485 protocolSystem checklist Thermostat bench testUnder the Settings tab, go Ascii setup Serial communication testHvac system testing Hvac system wiring exampleStandard Hvac system quick test Heat pump system quick testControl unit wiring Hvac system transformerDIP switch SW1 settings Serial network command and variable list Network commandsName Variable data Default value Network variablesContacting technical support Online publication librarySmartCommand Thermostat Installation Manual

CC-SCSTAT specifications

The GE CC-SCSTAT is a cutting-edge control system designed for power generation and distribution applications. This advanced platform is engineered to enhance efficiency, reliability, and safety in industrial environments, making it a preferred choice among operators in various sectors, including oil and gas, manufacturing, and utilities.

One of the main features of the GE CC-SCSTAT is its robust data acquisition and control capabilities. It integrates a comprehensive suite of sensors and monitoring tools that allow for real-time tracking of system performance. This functionality is crucial for identifying anomalies and optimizing operational parameters, ultimately leading to reduced downtime and increased productivity.

The system utilizes advanced communication protocols, such as Ethernet and Modbus, facilitating seamless integration with existing infrastructure. This interoperability ensures that organizations can implement the CC-SCSTAT without the need for extensive system overhauls, thus minimizing capital expenditure and disruption to ongoing operations.

In terms of technology, the GE CC-SCSTAT employs state-of-the-art algorithms for predictive maintenance and performance analytics. These capabilities are powered by machine learning and artificial intelligence, enabling the system to learn from historical data and predict potential failures before they occur. This proactive approach to maintenance not only extends the lifespan of equipment but also contributes to significant cost savings over time.

Another noteworthy characteristic of the CC-SCSTAT is its user-friendly interface, which provides operators with easy access to vital system information. The intuitive dashboard displays key performance indicators (KPIs), alarms, and alerts in a clear and organized manner, allowing for quick decision-making and response. Additionally, the system supports mobile access, enabling operators to monitor and control processes from remote locations.

Safety is a fundamental aspect of the GE CC-SCSTAT design. The system incorporates multiple layers of security features, including redundancy and failover mechanisms, ensuring continuous operation even in the event of a component failure. Furthermore, compliance with industry standards and regulations guarantees that the system adheres to best practices in safety and reliability.

In conclusion, the GE CC-SCSTAT stands out as a robust control system with advanced features and technologies. Its integration capabilities, predictive analytics, user-centric design, and unwavering focus on safety position it as a leading solution in the power generation and industrial control sectors. As organizations increasingly look to enhance operational efficiency and sustainability, the CC-SCSTAT proves to be a valuable asset in achieving these objectives.