5.Span setting mode – allows you to adjust the system ON/OFF

cycle rate. The default setting is 2 (the system cycles ON or OFF when the temperature is within 1o F (0.5o C) above and below the set temperature.) The span setting can be adjusted if your system is cycling too fast or too slowly.

Press and hold both the Up and Down buttons until the word SPAN appears. Use the Up or Down button to adjust the span setting.

(Up will increase your cycle time by allowing the system to run longer; Down will decrease your cycle time by causing the system to run for a shorter length of time.)

Span settings remain the same for HEAT and COOL system settings. When batteries are installed, or the unit is RESET, the span cycle will revert to 2.

47

Image 47
Contents Set & $ave Page Table of Contents Set & Save Important information Tools Page Page Uninstalling the existing unit RC / VC Wire labelsUninstalling the existing unit, Page Installing the Wall Plate Installing the thermostatPage Installing the thermostat, RC W/B Connecting the Wires Thermostat Cover System Switch Fan Attaching the Thermostat Front cover Tab Installing the thermostat, Reset Settings Day/time SETTINGS, Heat Methods of operation Heat Manual Operation / Override Methods of operationSystem Off Heat Cool Permanent Override Tod Home Today Override Set Temp Vacation Override Default Programs Chart Default Programs System Heat Program Off Cool Creating Custom Programs System Heat Off Cool Program Hold Return Methods of operation Filter Icons and Features Energy Icons and FEATURES, Reset Icons and FEATURES, Stage Icons and FEATURES, Hold Return Icons and FEATURES, Page Icons and FEATURES, Program Range Important featuresTroubleshooting Page Troubleshooting Is there help on the web? Can’t I just call someone?