Hunter Fan 42710-01 operation manual Uninstalling the existing unit

Page 11

uninstalling the existing unit, cont.

4.Using the provided stickers, label each wire according to the Wire Labels chart. (If the terminals are not labeled, contact a qualified HVAC technician.)

RC

Y

G

W

W

Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification.

*If wires marked Y & C are both present, C may be a Common wire and should not be used. If you have a wire

marked C, do not connect it to any terminal. This wire is used only for non-battery powered thermostats.

5.Do not let the wires slip back into the wall during disconnection. You may want to secure the wires to the wall as you disconnect them. After all wires are labeled, disconnect each wire and remove the existing wall plate.

(Any unused wires should be capped with an approved electrical connector, such as electrical tape.)

11

Image 11
Contents Set & $ave Page Table of Contents Set & Save Important information Tools Page Page Uninstalling the existing unit RC / VC Wire labelsUninstalling the existing unit, Page Installing the Wall Plate Installing the thermostatPage Installing the thermostat, RC W/B Connecting the Wires Thermostat Cover System Switch Fan Attaching the Thermostat Front cover Tab Installing the thermostat, Reset Settings Day/time SETTINGS, Heat Methods of operation Heat Manual Operation / Override Methods of operationSystem Off Heat Cool Permanent Override Tod Home Today Override Set Temp Vacation Override Default Programs Chart Default Programs System Heat Program Off Cool Creating Custom Programs System Heat Off Cool Program Hold Return Methods of operation Filter Icons and Features Energy Icons and FEATURES, Reset Icons and FEATURES, Stage Icons and FEATURES, Hold Return Icons and FEATURES, Page Icons and FEATURES, Program Range Important featuresTroubleshooting Page Troubleshooting Is there help on the web? Can’t I just call someone?