Operating functions.
Heat
•In this mode, the thermostat controls the heating system.
• Press the < or > buttons to set the desired temperature.
Standby
Set
Troubleshooting tips.
Problem | Solution | 
No display  | Check for 24 VAC at thermostat;  | 
  | display is blank when 24 VAC is  | 
  | not present .  | 
  | 
  | 
System fan does not  | Verify that wiring is correct .  | 
come on properly  | 
  | 
  | 
  | 
Thermostat turns on and  | Adjust temperature differential  | 
off too frequently  | (see Temperature Differential,  | 
  | Stage 1).  | 
  | 
  | 
Fan runs continuously  | Check Fan Auto/On switch. If set to  | 
  | ON position, fan will run continuously.  | 
  | 
  | 
Room temperature is  | Verify that wall hole is plugged  | 
not correct  | with putty or insulation; calibrate  | 
  | thermostat (see Configuration mode).  | 
  | 
  | 
Auxiliary heat not on  | Adjust differential for 2nd stage  | 
soon enough | (RAK148D1 only) heating, if required  | 
  | (see Configuration mode). | 
Compressor doesn’t run or turn off immediately when changing function or setting
There is a 3 minute time delay and a 3 minute minimum run time for the compressor when it turns on/off.
Fan doesn’t run or turn off  | This is normal. On some models, the  | 
immediately when changing  | fan may have a 3 minute minimum  | 
function or setting  | run time/off time delay.  | 
  | 
  | 
Problem not listed above  | Press the Reset button once;  | 
  | display will be refreshed.  | 