GE RAK148D1 Terminal designator descriptions, Starting the thermostat, Testing the thermostat

Page 10

Terminal designator descriptions.

R

24 VAC hot

G

Fan

C

24 VAC common

B

Heat active reversing

W

Aux. heat

 

 

valve (RAK148D1 only)

Y— Compressor

Starting the thermostat.

CAUTION! Do not use air conditioning when the outdoor temperature is below 50 degrees. This can damage your air conditioning system and cause personal injuries.

1.Move the Fan Auto/On switch to the Auto position.

2.Move the Function switch to Cool or Heat, depending on the season.

Testing the thermostat.

ROOM

Once the thermostat is installed, it should be thoroughly tested.

CAUTION! Do not use air conditioning when the outdoor temperature is below 50 degrees. This can damage your air conditioning system and cause personal injuries.

Cool Test

1.Slide Function switch to Cool mode.

2. Adjust set temperature so it is 5 degrees below room temperature.

3.Air conditioning should come on within a few seconds.

4.Adjust the set temperature so it is 2 degrees above the room temperature and the A/C should turn off. Note: There is a 3 minute time delay and a 3 minute minimum run time for the compressor when it turns on/off. (On some models, the fan may also have a 3 minute minimum run time/off time delay).

10

Image 10
Contents Installation Instructions ThermostatsImportant safety information SpecificationsIntroduction Overview Thermostat Control Installation Instructions To Install Thermostat Wiring diagrams Terminals for six wires 2 heat/1 cool system RAK148D1 only Setup screens for Configuration Mode are as follows Configuration modeConfiguration Mode Settings Button Press the SW6 button to advance to the next screenAdjust to calibrate displayed room Turns on and stage 2 turns onTerminal designator descriptions Testing the thermostatMove the Fan Auto/On switch to the Auto position Starting the thermostatFan Test Operating functionsHeat Test OffProblem Solution Troubleshooting tipsHeat Page Page Page Thermostat Warranty For The Period GE Will Replace